Skip to main content
Schneider Electric A9D77420

Schneider Electric A9D77420 Acti9 iC60 RCBO, 20A C-curve 30m

MPN A9D77420
Active

Schneider Electric Acti9 iC60 RCBO, 4P, 20 A rated, C-curve, 30 mA earth leakage, 6 kA breaking capacity, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9D77420 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage380...415 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
Breaking capacity6000 A Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1 6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2
Terminal pitch9 mm between poles
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
ColorWhite

All specifications

A9D77420 additional specifications
ParameterValue
Depth78 mm
Width72 mm
Height86 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

It carries a 20 A rated current on a C-curve trip characteristic and integrates 30 mA earth-leakage protection, so one device covers both the branch-circuit overcurrent and the personnel / equipment GFCI function on a three-phase outgoer. Breaking capacity is 6 kA Icu at 380…415 V AC 50 Hz per EN/IEC 60947-2, with an Icn of 6 kA per EN/IEC 61009-2-1. Clip-on mounting to DIN rail, 9 mm pole pitch, 72 mm wide × 86 mm high × 78 mm deep. IP40 in a distribution enclosure, IP20 on the terminals. The thermal-magnetic trip unit is field-proven in the Acti9 range; mechanical durability is 20,000 cycles, electrical 10,000 cycles.

Integration & wiring

Tunnel-type terminals top and bottom accept 1…35 mm² rigid, 1…25 mm² flexible, or 1…25 mm² flexible with ferrule. Tightening torque 2 N·m; strip length 12 mm. The 9 mm pole pitch matches standard Acti9 busbars and comb-bridge accessories. Local signalling shows ON, OFF, and fault-trip status via the toggle position. The device is intended as an outgoer in a distribution board — not a main incomer. The 30 mA earth-leakage threshold is the standard for personnel protection in most IEC-based installations.

MPN