Skip to main content
Schneider Electric A9D87416 — Residual Current Breakers (RCCB/RCBO)

A9D87416 Acti9 iC60 RCBO, 4P, 16 A, B Curve, 30 mA

MPNA9D87416
Active

Schneider Electric Acti9 iC60 RCBO, 4-pole, 16 A, B curve, 30 mA earth leakage, 6 kA breaking capacity, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9D87416 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON, OFF, fault trip
A9D87416 — Electrical Ratings
ParameterValue
Rated current (In)16 A
Rated operational voltage (Ue)380...415 V AC 50 Hz
Poles description4P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9D87416 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60 RCBO
A9D87416 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsTunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible Tunnel type terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length12 mm for top or bottom connection
Terminal tightening torque2 N.m
Width72 mm
Height86 mm
Depth78 mm
A9D87416 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529
Relative humidity95 % at 55 °C
Tropicalisation2
A9D87416 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 61009-2-1

Product details

The A9D87416 is a Schneider Electric Acti9 iC60 RCBO — a 4-pole residual-current circuit breaker with overcurrent protection, rated 16 A with a B tripping curve and 30 mA earth-leakage sensitivity.

The 30 mA earth-leakage threshold provides personnel protection per IEC 60364, catching fault currents to ground before they reach a dangerous level. Breaking capacity is 6000 A Icn at 380...415 V AC per EN/IEC 61009-2-1, and 6 kA Icu per EN/IEC 60947-2. The thermal-magnetic trip unit combines a bimetal strip for overload protection (16 A continuous) with a solenoid for short-circuit protection. The 250 A surge current rating confirms it can close onto a fault without welding contacts.

That's four pole widths — standard for a 4P RCBO. Depth is 78 mm, height 86 mm. Tightening torque 2 N.m. IP40 in an enclosure, IP20 bare. Local signalling shows ON, OFF, and fault trip status. The toggle control gives a clear visual of the contact position — useful for panel walk-downs. Connection pitch is 9 mm between poles, matching standard RCBO busbar spacing.

Frequently asked questions

What compliance documentation does this brand provide for A9D87416?

The A9D87416 is certified to EN/IEC 60947-2 and EN/IEC 61009-2-1, and carries quality labels KEMA-KEUR, NF, VDE, and IMQ. Overvoltage category III per IEC 60364.

MPN
A9D87416