Skip to main content
Schneider Electric A9DC2616 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DC2616 Acti9 iCV40 RCBO, 16 A, 30 mA, C

MPNA9DC2616
Active

Schneider Electric Acti9 iCV40 RCBO, 1P+N, 16 A, C-curve, 30 mA earth leakage, 4.5 kA breaking capacity, DIN rail mount.

$183.71Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9DC2616 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication Fault indication
A9DC2616 — Electrical Ratings
ParameterValue
Rated current (In)16 A
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DC2616 — Identification
ParameterValue
Product nameActi9 iCV40
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiCV40
A9DC2616 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height85 mm
Depth73 mm
A9DC2616 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Operating altitude2000 m
A9DC2616 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

It protects a final subcircuit against overload, short-circuit (thermal-magnetic trip, C-curve, magnetic tripping limit 5...10 x In), and earth leakage at 30 mA sensitivity, all in one 36 mm wide DIN-rail package.

Rated 16 A (In) with a C-curve — so it holds up to 16 A continuous load and trips magnetically between 5 and 10 times that (80–160 A) for short-circuit protection. Breaking capacity is 4.5 kA Icn at 230 V AC, 50/60 Hz, per EN/IEC 61009-2-1. Earth-leakage protection is integrated at 30 mA sensitivity — that is the standard threshold for personal protection against indirect contact (touch voltage) per IEC 60364. It covers the same circuit as the overcurrent protection, so no separate RCCB module needed.

Neutral is on the left, phase on the right — wire it accordingly. Tunnel terminals accept 1...16 mm² rigid or 1...10 mm² flexible; strip 14 mm, torque to 2 N.m. IP20 rated (finger-safe terminals), IP40 in a modular enclosure. Pollution degree 3, overvoltage category III — suitable for fixed installations inside a distribution board.

Frequently asked questions

Where can I buy the A9DC2616 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What are the key ratings of the A9DC2616?

16 A rated current, C-curve, 30 mA earth-leakage sensitivity, 4.5 kA breaking capacity at 230 V AC, 1P+N, DIN rail mount, thermal-magnetic trip.

What compliance documentation does Schneider provide for the A9DC2616?

The device is certified to EN/IEC 61009-2-1 and carries KEMA-KEUR and VDE quality labels. It meets the standards for fixed electrical installations per IEC 60364 (overvoltage category III, pollution degree 3).

MPN
A9DC2616