Skip to main content
Schneider Electric A9DC2916 — Residual Current Breakers (RCCB/RCBO)

A9DC2916 Acti9 iC60 RCBO, 16 A, 10 kA, 100 mA, Curve C

MPNA9DC2916
Active

Schneider Electric Acti9 iC60 series, RCBO (residual current breaker with overcurrent protection), 3P + Ns, 16 A rated, 10 kA breaking capacity at 400/415 V, 100 mA earth-leakage, curve C, A9DC2916.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9DC2916 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9DC2916 — Electrical Ratings
ParameterValue
Rated current (In)16 A at 30 °C
Rated operational voltage (Ue)400/415 V
Poles description3P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DC2916 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H3 RCBO
A9DC2916 — Mechanical
ParameterValue
Mounting supportDIN rail Chassis
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules6
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible
Wire stripping lengthPower circuit: 11 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 2.5 N.m top Power circuit: 2.5 N.m bottom
Width54 mm
Height112 mm
Depth77.2 mm
A9DC2916 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-25...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9DC2916 — Approvals
ParameterValue
StandardsAS/NZS 61009.1 IEC 61009-1 IEC 61009-2-2

Product details

It's rated 16 A at 30 °C with a 10,000 A Icn breaking capacity at 400/415 V (limitation class 3), so it handles fault currents up to that level without cascading upstream in a TN earthing system. The 100 mA earth-leakage sensitivity catches ground faults on three protected poles.

The neutral sits on the left; terminals accept 1–25 mm² rigid or 1–16 mm² flexible with screw clamps (2.5 N·m torque). Strip 11 mm for the bottom connection, 14 mm for the top. IP20 rated, so it's panel-internal only — no washdown exposure. Padlockable with a 4 mm Ø lock or lead seal for lockout/tagout.

Rated for 5,000 electrical cycles and 20,000 mechanical cycles — the thermal-magnetic trip unit is field-reliable for routine switching on outgoing circuits. Toggle control with ON/OFF local indication. Wire stripping lengths differ between top (14 mm) and bottom (11 mm) terminals; mixing them up leaves copper exposed or insufficient contact.

Frequently asked questions

What is the breaking capacity of the A9DC2916?

The A9DC2916 has a breaking capacity of 10,000 A Icn at 400/415 V, limitation class 3, which means it safely interrupts faults up to that level in a TN earthing system.

How do I get pricing and availability for the A9DC2916?

The A9DC2916 is sourced and quoted to order against an RFQ through independent distribution; current pricing and availability are confirmed at quote time.

What standards does the A9DC2916 comply with?

It complies with AS/NZS 61009.1, IEC 61009-1, and IEC 61009-2-2 for residual current breakers with overcurrent protection.

MPN