Schneider Electric A9DC2920 — Residual Current Breakers (RCCB/RCBO)

A9DC2920 Acti9 iC60 RCBO, 20 A, 10 kA, 100 mA, 3P+N

MPNA9DC2920
Active

Schneider Electric Acti9 iC60 RCBO, A9DC2920, 3P+N, 20 A rated, 10 kA Icn at 400/415 V, 100 mA earth-leakage sensitivity, C-curve, thermal-magnetic trip.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9DC2920 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9DC2920 — Electrical Ratings
ParameterValue
Rated current (In)20 A at 30 °C
Rated operational voltage (Ue)400/415 V
Poles description3P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DC2920 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H3 RCBO
A9DC2920 — Mechanical
ParameterValue
Mounting supportDIN rail Chassis
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules6
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible
Wire stripping lengthPower circuit: 11 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 2.5 N.m top Power circuit: 2.5 N.m bottom
Width54 mm
Height112 mm
Depth77.2 mm
A9DC2920 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-25...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9DC2920 — Approvals
ParameterValue
StandardsAS/NZS 61009.1 IEC 61009-1 IEC 61009-2-2

Product details

The Schneider Electric A9DC2920 is a 3P+N Acti9 iC60 RCBO — a combined residual-current device and miniature circuit breaker in one 54 mm wide module. The 20 A rated current and 10 kA Icn breaking capacity at 400/415 V mean it handles both overload and short-circuit faults on branch circuits up to that level, while the integrated 100 mA earth-leakage protection covers ground-fault detection without a separate RCCB. The C-curve gives a magnetic trip threshold of 5–10× In, suited to motor and lighting loads with moderate inrush.

The 100 mA earth-leakage sensitivity is a higher threshold than the 30 mA used for personal protection; it is typically specified for equipment protection or circuits where nuisance tripping from leakage is a concern. The thermal-magnetic trip unit combines a bimetal strip for overload protection and a solenoid for short-circuit response. Limitation class 3 means the device limits let-through energy during a fault, reducing stress on downstream components.

The neutral position is left. Screw-clamp terminals accept 1–25 mm² rigid or 1–16 mm² flexible with a tightening torque of 2.5 N.m. Wire stripping length is 11 mm for bottom connection and 14 mm for top connection. Padlockable with a 4 mm diameter padlock or lead seal. The toggle control provides ON/OFF indication.

Frequently asked questions

What is the closest alternative to A9DC2920 in the Acti9 family?

Within the Acti9 iC60 RCBO range, the closest alternative would differ in rated current (In) or earth-leakage sensitivity (IΔn). The A9DC2920 is a 20 A, 100 mA variant; a 16 A or 32 A version with the same 10 kA breaking capacity and 3P+N configuration would be a form-fit-function equivalent for a different load current. Check the spec line yourself — the pole count, curve, and leakage threshold must match your circuit design.

What compliance documentation does A9DC2920 carry?

The A9DC2920 complies with AS/NZS 61009.1, IEC 61009-1, and IEC 61009-2-2. These standards cover the RCBO-specific requirements for residual current and overcurrent protection. The IP20 rating is also listed.

Where can I buy A9DC2920 and how is it quoted?

The A9DC2920 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your volume.

MPN
A9DC2920