Schneider Electric A9DC2925 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DC2925 Acti9 iC60 RCBO, 25 A C-Curve, 1

MPNA9DC2925
Active

Schneider Electric Acti9 iC60 RCBO, 3P+N, 25 A, C-curve, 10 kA Icn at 400/415 V, 100 mA earth leakage, 6 module pitches.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9DC2925 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9DC2925 — Electrical Ratings
ParameterValue
Rated current (In)25 A at 30 °C
Rated operational voltage (Ue)400/415 V
Poles description3P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DC2925 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H3 RCBO
A9DC2925 — Mechanical
ParameterValue
Mounting supportDIN rail Chassis
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules6
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible
Wire stripping lengthPower circuit: 11 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 2.5 N.m top Power circuit: 2.5 N.m bottom
Width54 mm
Height112 mm
Depth77.2 mm
A9DC2925 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-25...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9DC2925 — Approvals
ParameterValue
StandardsAS/NZS 61009.1 IEC 61009-1 IEC 61009-2-2

Product details

It carries a 25 A rated current (C-curve) and a 10 kA Icn breaking capacity at 400/415 V, with 100 mA earth-leakage sensitivity.

At 54 mm wide (6 module pitches of 9 mm), it occupies the same footprint as a 3P+N MCB — no extra space needed for the earth-leakage section. Depth is 77.2 mm, height 112 mm.

The 100 mA earth-leakage threshold is a protection level for equipment and fire prevention, not personnel (30 mA is the touch-safe threshold). Use it on TN earthing systems as an outgoing device.

Rated for 50/60 Hz networks, IP20 finger-safe terminals, and tropicalised (class 2) for humid environments — 95% relative humidity at 55 °C. Complies with AS/NZS 61009.1, IEC 61009-1, and IEC 61009-2-2. Padlockable with a 4 mm padlock or lead seal for lockout/tagout.

Frequently asked questions

What is the breaking capacity of A9DC2925?

The A9DC2925 has a 10 kA Icn breaking capacity at 400/415 V AC, sufficient for most sub-distribution boards.

What earth-leakage sensitivity does A9DC2925 have?

It is set to 100 mA earth-leakage sensitivity, suitable for equipment and fire protection, not personnel shock protection.

How do I get pricing and availability for A9DC2925?

The A9DC2925 is sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time.

What is the width of A9DC2925 in module pitches?

It occupies 6 module pitches (54 mm wide), the same as a standard 3P+N MCB.

What standards does A9DC2925 comply with?

It complies with AS/NZS 61009.1, IEC 61009-1, and IEC 61009-2-2 for RCBOs.

MPN
A9DC2925