Skip to main content
Schneider Electric A9DC2940 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DC2940 Acti9 iC60H3 RCBO, 40 A, 10 kA,

MPNA9DC2940
Active

Schneider Electric Acti9 iC60H3 RCBO, 3P + Ns, 40 A, curve C, 10 kA Icn at 400/415 V, 100 mA earth-leakage sensitivity, integrated protection, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9DC2940 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)100 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9DC2940 — Electrical Ratings
ParameterValue
Rated current (In)40 A at 30 °C
Rated operational voltage (Ue)400/415 V
Poles description3P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DC2940 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H3 RCBO
A9DC2940 — Mechanical
ParameterValue
Mounting supportDIN rail Chassis
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules6
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible
Wire stripping lengthPower circuit: 11 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 2.5 N.m top Power circuit: 2.5 N.m bottom
Width54 mm
Height112 mm
Depth77.2 mm
A9DC2940 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-25...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9DC2940 — Approvals
ParameterValue
StandardsAS/NZS 61009.1 IEC 61009-1 IEC 61009-2-2

Product details

Schneider Electric A9DC2940 is an Acti9 iC60H3 RCBO — a 3-pole plus neutral residual current breaker with overcurrent protection, rated 40 A at 30 °C, curve C, with 10 kA Icn breaking capacity at 400/415 V and 100 mA earth-leakage sensitivity. The thermal-magnetic trip unit handles both overload and short-circuit; the integrated earth-leakage module covers ground faults. Clip-on mounting on DIN rail or chassis, 54 mm wide (6 x 9 mm pitches), 77.2 mm deep, 112 mm high. IP20 finger-safe terminals.

The curve C trip characteristic (5–10 x In) means it tolerates moderate inrush from motor or transformer loads without nuisance tripping. The 100 mA earth-leakage sensitivity is a general-purpose ground-fault protection level, not the 30 mA required for personal shock protection in socket-outlet circuits — it's sized for equipment protection and fire prevention on outgoing feeders. Limitation class 3 (energy-limiting) means it restricts let-through energy under fault conditions, reducing stress on downstream wiring and devices.

Clip-on mounting on DIN rail or chassis. The 54 mm width (6 x 9 mm pitches) fits standard modular enclosures. Wire stripping length: 11 mm for bottom connection, 14 mm for top. Tightening torque: 2.5 N·m both top and bottom. Neutral position is left; the device is padlockable with a Ø 4 mm padlock or lead seal. ON/OFF indication via toggle. Tropicalisation class 2 for humid environments (95% RH at 55 °C).

Frequently asked questions

Where can I buy A9DC2940 and how do I get a price?

The A9DC2940 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What are the key ratings of A9DC2940?

40 A rated current at 30 °C, curve C, 10 kA Icn breaking capacity at 400/415 V, 100 mA earth-leakage sensitivity, 3P + Ns poles, thermal-magnetic trip, integrated earth-leakage protection.

What compliance documentation does this brand provide for A9DC2940?

The A9DC2940 is certified to AS/NZS 61009.1, IEC 61009-1, and IEC 61009-2-2. These standards cover the RCBO's construction, performance, and test requirements for residual current and overcurrent protection.

MPN