Skip to main content
Schneider Electric A9DC4706 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DC4706 Acti9 iCV40H RCBO, 6 A, 30 mA, C

MPNA9DC4706
Active

Schneider Electric Acti9 iCV40H RCBO, A9DC4706, 6 A rated, 30 mA earth-leakage sensitivity, C-curve, 10 kA breaking capacity at 400 V AC, 3P+N, DIN-rail mount.

$256.50Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9DC4706 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication Fault indication
A9DC4706 — Electrical Ratings
ParameterValue
Rated current (In)6 A
Rated operational voltage (Ue)400 V AC 50/60 Hz
Poles description3P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)440 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DC4706 — Identification
ParameterValue
Product nameActi9 iCV40
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiCV40H
A9DC4706 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules10
Terminal connectionsTunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width90 mm
Height93 mm
Depth73 mm
A9DC4706 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Operating altitude2000 m
A9DC4706 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

The Schneider Electric A9DC4706 is an Acti9 iCV40H RCBO — a combined overcurrent and earth-leakage protective device — rated 6 A with 30 mA sensitivity, C-curve, and a 10 kA breaking capacity at 400 V AC per EN/IEC 61009-2-1. It protects three poles plus neutral in a single modular unit, so it fits a 3P+N outgoing circuit where you need both short-circuit and ground-fault protection in one DIN-rail package.

The 30 mA earth-leakage sensitivity provides additional protection against indirect contact and fire risk from ground faults, integrated into the same thermal-magnetic trip unit. That means one device replaces a separate MCB and RCD in the same DIN-rail width — 10 module pitches (90 mm wide) for the 3P+N configuration.

Clip-on mounting to a standard DIN rail. Neutral is on the left; connection pitch is 18 mm between phases and 9 mm between phase and neutral. Tunnel-type terminals accept 1–16 mm² rigid or 1–10 mm² flexible cable; strip length is 14 mm, tighten to 2 N·m. IP20 rated (IP40 in modular enclosure).

Frequently asked questions

What is A9DC4706's listed depth (73 mm) on this component line?

The depth is 73 mm, with a height of 93 mm and a width of 90 mm (10 module pitches). These dimensions fit standard modular enclosure cutouts.

MPN