Skip to main content
Schneider Electric A9DC5910 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DC5910 Acti9 iC60 RCBO, 10 A, 6 kA, 10

MPNA9DC5910
Active

Schneider Electric Acti9 iC60 RCBO, A9DC5910, 3P+N, 10 A rated current, 6 kA Icn at 400/415 V, 10 mA earth-leakage sensitivity, C-curve, thermal-magnetic trip, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9DC5910 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)10 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9DC5910 — Electrical Ratings
ParameterValue
Rated current (In)10 A at 30 °C
Rated operational voltage (Ue)400/415 V
Poles description3P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DC5910 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60N3 RCBO
A9DC5910 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules6
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end
Wire stripping lengthPower circuit: 11 mm for bottom connection
Terminal tightening torquePower circuit: 2.5 N.m top
Width54 mm
Height112 mm
Depth77.2 mm
A9DC5910 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-25...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9DC5910 — Approvals
ParameterValue
StandardsAS/NZS 61009.1

Product details

The A9DC5910 is a 3P+N residual current breaker with overcurrent protection (RCBO) from the Acti9 iC60 family. It combines a C-curve MCB (10 A rated current, 6 kA Icn at 400/415 V) with an integrated 10 mA earth-leakage module in one 54 mm wide DIN-rail unit. The 10 mA sensitivity catches leakage paths that a 30 mA device would miss — think medical equipment, wet areas, or circuits where a lower trip threshold is specified for personnel protection.

Clip-on mount to DIN rail, 6 x 9 mm pitches wide (54 mm). Neutral on the left. Torque to 2.5 N·m. IP20 finger-safe — panelboard use, not washdown.

Frequently asked questions

What are the key ratings of the A9DC5910?

Rated current 10 A at 30 °C, breaking capacity 6 kA Icn at 400/415 V, earth-leakage sensitivity 10 mA, C-curve, thermal-magnetic trip, 3P+N, 50/60 Hz.

Where can I buy the A9DC5910 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

MPN
A9DC5910