Schneider Electric A9DC5916 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DC5916 Acti9 iC60 RCBO, 16A C-curve 10m

MPNA9DC5916
Active

Schneider Electric Acti9 iC60 RCBO, 3P + Ns, 16 A, C-curve, 10 mA earth leakage, 6000 A Icn at 400/415 V, clip-on DIN rail, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9DC5916 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)10 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9DC5916 — Electrical Ratings
ParameterValue
Rated current (In)16 A at 30 °C
Rated operational voltage (Ue)400/415 V
Poles description3P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DC5916 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60N3 RCBO
A9DC5916 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules6
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end
Wire stripping lengthPower circuit: 11 mm for bottom connection
Terminal tightening torquePower circuit: 2.5 N.m top
Width54 mm
Height112 mm
Depth77.2 mm
A9DC5916 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-25...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9DC5916 — Approvals
ParameterValue
StandardsAS/NZS 61009.1

Product details

It carries a 16 A rated current (C-curve) and a 10 mA earth-leakage sensitivity, with a 6 kA breaking capacity at 400/415 V. The thermal-magnetic trip unit handles both overload and short-circuit protection, while the integrated earth-leakage module catches ground faults down to 10 mA. That sensitivity level is typically specified for circuits where additional protection against electric shock is required — think socket outlets in wet areas or circuits supplying portable equipment.

The unit occupies 6 x 9 mm pitches (54 mm width) on the rail. Neutral is on the left, with screw-clamp terminals accepting 1...25 mm² rigid cable. The IP20 enclosure means it's suited for installation inside a distribution board or enclosure, not for wet or outdoor locations without additional protection. Padlockable with a 4 mm padlock for lockout/tagout procedures.

Certified to AS/NZS 61009.1, the Australian/New Zealand standard for RCBOs. Rated for TN earthing systems and AC networks at 50/60 Hz. Limitation class 3 indicates good current-limiting performance, reducing let-through energy on faults.

Frequently asked questions

What is the breaking capacity of the A9DC5916?

The breaking capacity is 6000 A Icn at 400/415 V, which is the standard rating for this RCBO frame size.

What earth-leakage sensitivity does the A9DC5916 have?

The integrated earth-leakage protection is set at 10 mA sensitivity, suitable for circuits requiring additional shock protection.

MPN
A9DC5916