Schneider Electric A9DC5920 — Residual Current Breakers (RCCB/RCBO)

A9DC5920 Acti9 iC60 RCBO, 20 A, C-curve, 6 kA, 10 mA

MPNA9DC5920
Active

Schneider Electric Acti9 iC60 RCBO, A9DC5920, 3P + N, 20 A, C-curve, 6 kA Icn at 400/415 V, 10 mA earth-leakage sensitivity, thermal-magnetic trip, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9DC5920 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)10 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9DC5920 — Electrical Ratings
ParameterValue
Rated current (In)20 A at 30 °C
Rated operational voltage (Ue)400/415 V
Poles description3P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DC5920 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60N3 RCBO
A9DC5920 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules6
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end
Wire stripping lengthPower circuit: 11 mm for bottom connection
Terminal tightening torquePower circuit: 2.5 N.m top
Width54 mm
Height112 mm
Depth77.2 mm
A9DC5920 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-25...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9DC5920 — Approvals
ParameterValue
StandardsAS/NZS 61009.1

Product details

It combines a 20 A thermal-magnetic MCB (C-curve) with integrated 10 mA earth-leakage protection, all in a 3P + Ns pole configuration. The 6 kA Icn breaking capacity at 400/415 V covers the fault-current duty of most commercial and light-industrial final subcircuits. Clip-on mounting to DIN rail, 54 mm wide (6 x 9 mm pitches), with screw-clamp terminals accepting 1…25 mm² rigid cable.

The 20 A rated current at 30 °C sets the continuous load limit for the protected circuit — sized for lighting, socket outlets, or small equipment banks. The 10 mA earth-leakage sensitivity is below the standard 30 mA for socket-outlet circuits; this RCBO would be specified where personnel protection or equipment sensitivity demands a lower leakage threshold — think medical locations, wet areas, or circuits feeding sensitive electronics. The 6 kA Icn at 400/415 V is the short-circuit breaking capacity; in a TN earthing system with a prospective fault current below 6 kA, this unit coordinates without upstream reinforcement.

Panel integration

Clip-on mounting to DIN rail with a 45 mm grid distance. The 54 mm width occupies six 9 mm pitches on the rail — plan panel fill accordingly. Screw-clamp terminals on top accept 1…25 mm² rigid cable; wire strip length 11 mm for bottom connection. Tightening torque 2.5 N.m. Neutral position is left, important when laying out busbar links or pre-wired distribution blocks. IP20 means no washdown tolerance; keep this inside a closed panel or enclosure.

Frequently asked questions

Where can I buy A9DC5920?

The A9DC5920 is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

What is the breaking capacity of A9DC5920?

The A9DC5920 has a breaking capacity of 6000 A Icn at 400/415 V, which covers fault currents up to that level in a TN earthing system.

What earth-leakage sensitivity does A9DC5920 have?

The integrated earth-leakage protection is set at 10 mA sensitivity, lower than the standard 30 mA — suited for personnel protection in wet areas or sensitive equipment circuits.

What compliance standards does A9DC5920 meet?

The A9DC5920 complies with AS/NZS 61009.1, the standard for residual current operated circuit breakers with integral overcurrent protection for household and similar uses.

MPN
A9DC5920