A9DC5920 Acti9 iC60 RCBO, 20 A, C-curve, 6 kA, 10 mA

MPN A9DC5920
Active

Schneider Electric Acti9 iC60 RCBO, A9DC5920, 3P + N, 20 A, C-curve, 6 kA Icn at 400/415 V, 10 mA earth-leakage sensitivity, thermal-magnetic trip, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9DC5920 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage400/415 V
Insulation voltage ui500 V
Breaking capacity6000 A Icn at 400/415 V
IP ratingIP20
Temp storage max70 °C
Temp storage min-25 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-25...70 °C
ColorWhite
Depth77.2 mm
Width54 mm
Height112 mm
Electrical life cycles5000 cycles
Mechanical life cycles20000 cycles
Operating temperature-5...60 °C

Product details

It combines a 20 A thermal-magnetic MCB (C-curve) with integrated 10 mA earth-leakage protection, all in a 3P + Ns pole configuration. The 6 kA Icn breaking capacity at 400/415 V covers the fault-current duty of most commercial and light-industrial final subcircuits. Clip-on mounting to DIN rail, 54 mm wide (6 x 9 mm pitches), with screw-clamp terminals accepting 1…25 mm² rigid cable.

The 20 A rated current at 30 °C sets the continuous load limit for the protected circuit — sized for lighting, socket outlets, or small equipment banks. The 10 mA earth-leakage sensitivity is below the standard 30 mA for socket-outlet circuits; this RCBO would be specified where personnel protection or equipment sensitivity demands a lower leakage threshold — think medical locations, wet areas, or circuits feeding sensitive electronics. The 6 kA Icn at 400/415 V is the short-circuit breaking capacity; in a TN earthing system with a prospective fault current below 6 kA, this unit coordinates without upstream reinforcement.

Panel integration

Clip-on mounting to DIN rail with a 45 mm grid distance. The 54 mm width occupies six 9 mm pitches on the rail — plan panel fill accordingly. Screw-clamp terminals on top accept 1…25 mm² rigid cable; wire strip length 11 mm for bottom connection. Tightening torque 2.5 N.m. Neutral position is left, important when laying out busbar links or pre-wired distribution blocks. IP20 means no washdown tolerance; keep this inside a closed panel or enclosure.