Schneider Electric A9DC6916 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DC6916 Acti9 iC60 RCBO, 16 A C-curve, 3

MPNA9DC6916
Active

Schneider Electric Acti9 iC60 RCBO, 3P + Ns, 16 A rated current at 30 °C, C-curve, 30 mA earth-leakage sensitivity, 6 kA Icn breaking capacity at 400/415 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Residual Current Protection

A9DC6916 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication

Electrical Ratings

A9DC6916 — Electrical Ratings
ParameterValue
Rated current (In)16 A at 30 °C
Rated operational voltage (Ue)400/415 V
Poles description3P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles

Identification

A9DC6916 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60N3 RCBO

Mechanical

A9DC6916 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules6
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end
Wire stripping lengthPower circuit: 11 mm for bottom connection
Terminal tightening torquePower circuit: 2.5 N.m top
Width54 mm
Height112 mm
Depth77.2 mm

Environmental

A9DC6916 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-25...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2

Approvals

A9DC6916 — Approvals
ParameterValue
StandardsAS/NZS 61009.1

Product details

The 30 mA earth-leakage sensitivity covers personnel protection per AS/NZS 61009.1. Limitation class 3 (energy-limiting) means it clears a fault fast enough to restrict let-through energy, which helps with downstream device coordination and reduces arc-flash risk on the panel side.

Clip-on mounting to a 45 mm grid DIN rail, standard for European-style distribution boards. Occupies 6 x 9 mm pitches (54 mm wide), 112 mm tall, 77.2 mm deep — fits a standard 4-module slot in a residential or light-commercial consumer unit. IP20 rated, so it belongs inside a closed enclosure, not in a washdown area. Padlockable with a 4 mm hasp for lockout/tagout. ON/OFF indicator on the toggle gives a visible state check without opening the cover. Tropicalisation class 2 means it's treated for damp-heat environments up to 95% RH at 55 °C — relevant for coastal or unconditioned plant rooms.

Frequently asked questions

What is the breaking capacity of the A9DC6916?

6000 A Icn at 400/415 V, which is the standard fault-interruption rating for this class of RCBO in residential and light-commercial distribution boards.

What is the A9DC6916 used for?

It's a combined residual current breaker with overcurrent protection (RCBO) for a 3-phase outgoer circuit. It protects against earth leakage (30 mA sensitivity) and overcurrent/short-circuit (16 A, C-curve) in a single DIN-rail module.

Where can I buy the A9DC6916?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quotation.

MPN
A9DC6916