Schneider Electric A9DC6920 — Residual Current Breakers (RCCB/RCBO)

A9DC6920 Acti9 iC60 RCBO, 20 A, 30 mA, 6 kA, 3P+N

MPNA9DC6920
Active

Schneider Electric Acti9 iC60 RCBO, 3P+N, 20 A rated current, 30 mA earth-leakage sensitivity, 6 kA breaking capacity at 400/415 V, thermal-magnetic trip, clip-on DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Residual Current Protection

A9DC6920 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication

Electrical Ratings

A9DC6920 — Electrical Ratings
ParameterValue
Rated current (In)20 A at 30 °C
Rated operational voltage (Ue)400/415 V
Poles description3P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles

Identification

A9DC6920 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60N3 RCBO

Mechanical

A9DC6920 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules6
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end
Wire stripping lengthPower circuit: 11 mm for bottom connection
Terminal tightening torquePower circuit: 2.5 N.m top
Width54 mm
Height112 mm
Depth77.2 mm

Environmental

A9DC6920 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-25...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2

Approvals

A9DC6920 — Approvals
ParameterValue
StandardsAS/NZS 61009.1

Product details

The Schneider Electric A9DC6920 is an Acti9 iC60 RCBO — a residual current breaker with overcurrent protection, combining a 20 A thermal-magnetic MCB and a 30 mA earth-leakage module in one 54 mm wide, 3P+N unit. Its 6 kA Icn breaking capacity at 400/415 V is rated for TN earthing systems on AC networks at 50/60 Hz, making it a standard outgoer device for final subcircuits in commercial and light industrial distribution boards.

The 20 A rated current (at 30 °C) sets the continuous load limit for the thermal-magnetic trip; the C-curve characteristic means it holds up to 5–10× In for short-duration inrush, so it suits mixed resistive-inductive loads like lighting banks or small motor circuits. The 30 mA earth-leakage sensitivity provides personnel protection (indirect contact) per AS/NZS 61009.1 — the standard this unit is certified to. The 6 kA Icn breaking capacity at 400/415 V is the maximum prospective fault current the device can safely interrupt; for installations with higher available fault current, a current-limiting upstream device is needed to keep the let-through within the 6 kA rating.

Clip-on mounting to a 45 mm grid DIN rail (standard EN 60715). The 54 mm width occupies 6 modules of 9 mm pitch. Wire strip length is 11 mm for the bottom connection. The unit is padlockable with a Ø 4 mm padlock for lockout/tagout.

Frequently asked questions

What is the A9DC6920's breaking capacity?

6 kA Icn at 400/415 V AC, per AS/NZS 61009.1. This is the maximum prospective fault current the device can safely interrupt under standard test conditions.