Skip to main content
Schneider Electric A9DC6920

A9DC6920 Acti9 iC60 RCBO, 20 A, 30 mA, 6 kA, 3P+N

MPN A9DC6920
Active

Schneider Electric Acti9 iC60 RCBO, 3P+N, 20 A rated current, 30 mA earth-leakage sensitivity, 6 kA breaking capacity at 400/415 V, thermal-magnetic trip, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9DC6920 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage400/415 V
Insulation voltage ui500 V
Breaking capacity6000 A Icn at 400/415 V
IP ratingIP20
Temp storage max70 °C
Temp storage min-25 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-25...70 °C
ColorWhite
Depth77.2 mm
Width54 mm
Height112 mm
Electrical life cycles5000 cycles
Mechanical life cycles20000 cycles
Operating temperature-5...60 °C

Product details

The Schneider Electric A9DC6920 is an Acti9 iC60 RCBO — a residual current breaker with overcurrent protection, combining a 20 A thermal-magnetic MCB and a 30 mA earth-leakage module in one 54 mm wide, 3P+N unit. Its 6 kA Icn breaking capacity at 400/415 V is rated for TN earthing systems on AC networks at 50/60 Hz, making it a standard outgoer device for final subcircuits in commercial and light industrial distribution boards.

The 20 A rated current (at 30 °C) sets the continuous load limit for the thermal-magnetic trip; the C-curve characteristic means it holds up to 5–10× In for short-duration inrush, so it suits mixed resistive-inductive loads like lighting banks or small motor circuits. The 30 mA earth-leakage sensitivity provides personnel protection (indirect contact) per AS/NZS 61009.1 — the standard this unit is certified to. The 6 kA Icn breaking capacity at 400/415 V is the maximum prospective fault current the device can safely interrupt; for installations with higher available fault current, a current-limiting upstream device is needed to keep the let-through within the 6 kA rating.

Clip-on mounting to a 45 mm grid DIN rail (standard EN 60715). The 54 mm width occupies 6 modules of 9 mm pitch. Wire strip length is 11 mm for the bottom connection. The unit is padlockable with a Ø 4 mm padlock for lockout/tagout.

MPN