Schneider Electric A9DC6925 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DC6925 Acti9 iC60 RCBO, 25 A, 30 mA, 6

MPNA9DC6925
Active

Schneider Electric Acti9 iC60 RCBO, 3P + Ns, 25 A rated current, 30 mA earth-leakage sensitivity, 6 kA breaking capacity at 400/415 V, C-curve, thermal-magnetic trip, DIN-rail clip-on.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Residual Current Protection

A9DC6925 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication

Electrical Ratings

A9DC6925 — Electrical Ratings
ParameterValue
Rated current (In)25 A at 30 °C
Rated operational voltage (Ue)400/415 V
Poles description3P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles

Identification

A9DC6925 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60N3 RCBO

Mechanical

A9DC6925 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules6
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end
Wire stripping lengthPower circuit: 11 mm for bottom connection
Terminal tightening torquePower circuit: 2.5 N.m top
Width54 mm
Height112 mm
Depth77.2 mm

Environmental

A9DC6925 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-25...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2

Approvals

A9DC6925 — Approvals
ParameterValue
StandardsAS/NZS 61009.1

Product details

The Schneider Electric A9DC6925 is a 3P + Ns Acti9 iC60 RCBO — a combined residual current breaker with overcurrent protection (RCBO) — rated 25 A at 30 °C with an integrated 30 mA earth-leakage sensitivity. Its 6 kA breaking capacity (Icn at 400/415 V) and C-curve thermal-magnetic trip make it a standard choice for final subcircuit protection in TN earthing systems on 50/60 Hz AC networks. The 6 kA Icn at 400/415 V means this RCBO safely interrupts a fault current up to 6 kA without welding its contacts or failing to clear — that is the standard domestic and light-commercial fault level under AS/NZS 61009.1, so it is sized for most distribution boards downstream of a higher-rated upstream device. The 30 mA earth-leakage sensitivity provides additional protection against electric shock for people and equipment, meeting typical socket-outlet and lighting circuit requirements in residential and commercial installations.

Clip-on mounting to standard DIN rail (35 mm). The device occupies 6 x 9 mm pitches (54 mm width) and fits a 45 mm grid distance. Dimensions: 112 mm height, 77.2 mm depth. Tightening torque 2.5 N·m for the power circuit. Neutral position is left; padlockable with a Ø 4 mm padlock for lockout/tagout.

Standards compliance: AS/NZS 61009.1 (Australian/New Zealand standard for RCBOs). Tropicalisation class 2, relative humidity 95% at 55 °C. Electrical durability 5000 cycles, mechanical durability 20000 cycles. Limitation class 3.

Frequently asked questions

What is A9DC6925's listed depth?

The A9DC6925 has a depth of 77.2 mm.

What is A9DC6925's listed range?

The A9DC6925 belongs to the Acti9 range from Schneider Electric.

What compliance documentation does this brand provide for A9DC6925?

The A9DC6925 complies with AS/NZS 61009.1. For RoHS, REACH, or other documentation, request it with your RFQ.

MPN