Schneider Electric A9DC6950 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DC6950 Acti9 iC60 RCBO, 50 A C-curve, 3

MPNA9DC6950
Active

Schneider Electric Acti9 iC60 RCBO, 3P + Ns, 50 A rated current at 30 °C, C-curve, 30 mA earth-leakage sensitivity, 6 kA breaking capacity at 400/415 V, clip-on DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Residual Current Protection

A9DC6950 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication

Electrical Ratings

A9DC6950 — Electrical Ratings
ParameterValue
Rated current (In)50 A at 30 °C
Rated operational voltage (Ue)400/415 V
Poles description3P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles

Identification

A9DC6950 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60N3 RCBO

Mechanical

A9DC6950 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules6
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end
Wire stripping lengthPower circuit: 11 mm for bottom connection
Terminal tightening torquePower circuit: 2.5 N.m top
Width54 mm
Height112 mm
Depth77.2 mm

Environmental

A9DC6950 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-25...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2

Approvals

A9DC6950 — Approvals
ParameterValue
StandardsAS/NZS 61009.1

Product details

It protects a 3-phase + neutral outgoing circuit against overloads, short-circuits, and earth leakage in a single 54 mm wide package. Breaking capacity is 6 kA Icn at 400/415 V AC, 50/60 Hz, which covers most commercial and light industrial distribution boards where the prospective fault current stays below that level. The limitation class 3 rating means it lets through less energy during a fault, helping downstream selectivity.

Clip-on mounting to standard 35 mm DIN rail. The 54 mm width occupies 6 modules of 9 mm pitch. Depth is 77.2 mm, height 112 mm — fits standard distribution enclosures without crowding the door or busbar shroud. Tightening torque is 2.5 N.m. Wire strip length is 11 mm for bottom connections. Neutral is on the left, and the toggle provides local ON/OFF indication. Padlockable with a Ø 4 mm padlock for lockout/tagout during maintenance.

Designed and certified to AS/NZS 61009.1, the Australia/New Zealand standard for RCBOs. Suitable for TN earthing systems. Tropicalisation level 2 indicates treatment against humidity and corrosion for warm, damp environments. Relative humidity tolerance of 95% at 55 °C covers most non-condensing indoor installations.

Frequently asked questions

What is the earth-leakage sensitivity of this RCBO?

The integrated earth-leakage protection trips at 30 mA sensitivity. This is the standard threshold for personal protection against direct contact with live parts.

MPN
A9DC6950