Schneider Electric A9DC7710

Schneider Electric A9DC7710 Acti9 iCV40 10A RCBO, 30mA, C-Cu

MPN A9DC7710
Active

Schneider Electric Acti9 iCV40 RCBO, A9DC7710, 10 A, C-curve, 30 mA earth leakage, 3P+N, 6 kA breaking capacity, DIN rail mount, white.

$237.28 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9DC7710 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz
Breaking capacity6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch18 mm between phases 9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9DC7710 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width90 mm
Height93 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9DC7710 is an Acti9 iCV40 RCBO — a combined residual-current circuit breaker with overcurrent protection, rated 10 A with a C-curve magnetic trip characteristic (5...10 x In) and integrated 300 mA earth-leakage sensitivity. It protects a 3P+N outgoing circuit against overload, short-circuit, and earth faults in one 4-module-wide (72 mm) DIN-rail unit, saving panel space over separate MCB+RCCB.

The 10 A rated current (In) and C-curve mean the breaker holds 10 A indefinitely and trips magnetically between 50 A and 100 A — suited for general-purpose loads like lighting banks, small motor circuits, and socket outlets where inrush is moderate. The 300 mA earth-leakage threshold is a protection against fire risk from persistent leakage, not personnel shock (that needs 30 mA or lower); it's common on distribution outgoers feeding sub-distribution boards or fixed equipment where nuisance tripping from capacitive leakage must be avoided. Limitation class 3 (energy let-through) means it restricts the peak let-through energy under fault — helps with downstream coordination and reduces stress on cables and connected equipment.

Clip-on mounting on a DIN rail — 9 mm pitch, 10 pitches wide (90 mm). Neutral is on the left (3P+N). Connection pitch is 18 mm between phases, 9 mm between phase and neutral. Tunnel terminals accept 1...16 mm² rigid or 1...10 mm² flexible cable; strip 14 mm and torque to 2 N.m. The toggle control gives clear ON/OFF and fault indication on the front face.

MPN
A9DC7710