Schneider Electric A9DD1916 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DD1916 Acti9 iC60 RCBO, D Curve, 16 A,

MPNA9DD1916
Active

Schneider Electric Acti9 iC60 RCBO, 3P+N, D curve, 16 A rated current, 30 mA earth-leakage sensitivity, 10 kA breaking capacity at 400/415 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9DD1916 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage dependent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9DD1916 — Electrical Ratings
ParameterValue
Rated current (In)16 A at 30 °C
Rated operational voltage (Ue)400/415 V
Poles description3P + Ns
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durability5000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DD1916 — Identification
ParameterValue
Product nameActi9 iC60 RCBO
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiC60H3 RCBO
A9DD1916 — Mechanical
ParameterValue
Mounting supportDIN rail Chassis
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules6
Terminal connectionsScrew clamp terminal (top) 1...25 mm² rigid without cable end Screw clamp terminal (top) 1...16 mm² flexible
Wire stripping lengthPower circuit: 11 mm for bottom connection Power circuit: 14 mm for top connection
Terminal tightening torquePower circuit: 2.5 N.m top Power circuit: 2.5 N.m bottom
Width54 mm
Height112 mm
Depth77.2 mm
A9DD1916 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-25...70 °C
IP degree of protectionIP20
Relative humidity95 % at 55 °C
Tropicalisation2
A9DD1916 — Approvals
ParameterValue
StandardsAS/NZS 61009.1 IEC 61009-1 IEC 61009-2-2

Product details

The A9DD1916 is a Schneider Electric Acti9 iC60 RCBO — a residual current breaker with overcurrent protection, combining a D-curve MCB and a 30 mA earth-leakage module in one 3P+N unit.

Deployment context

Clip-on mounting onto DIN rail or chassis — standard for panel integration. The 54 mm width and 6 x 9 mm pitch occupy six modular spaces in a distribution board. The neutral is fixed left; verify busbar orientation before wiring.

Certified to AS/NZS 61009.1, IEC 61009-1, and IEC 61009-2-2 — covers residual current and overcurrent protection for household and similar installations. The thermal-magnetic trip unit provides both overload and short-circuit protection.

Frequently asked questions

What is the breaking capacity of A9DD1916?

10,000 A Icn at 400/415 V per IEC 61009-1, suitable for most commercial and light industrial sub-distribution boards.

What is A9DD1916's earth-leakage sensitivity?

30 mA — provides personnel protection against earth faults.

Where can I buy A9DD1916?

This part is sourced and quoted to order against an RFQ through independent distribution. Contact us for current pricing and availability.

What compliance documentation does Schneider provide for A9DD1916?

The part is certified to AS/NZS 61009.1, IEC 61009-1, and IEC 61009-2-2. RoHS and REACH declarations are typically available from Schneider Electric's documentation portal.

MPN
A9DD1916