Schneider Electric A9DE6616 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DE6616 Acti9 iCV40 RCBO, 16 A, 30 mA, C

MPNA9DE6616
Active

Schneider Electric Acti9 iCV40 RCBO, A9DE6616, 1P+N, 16 A, C-curve, 300 mA earth leakage, 4.5 kA breaking capacity, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9DE6616 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationFault indication ON/OFF indication
A9DE6616 — Electrical Ratings
ParameterValue
Rated current (In)16 A
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DE6616 — Identification
ParameterValue
Product nameActi9 iCV40
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiCV40
A9DE6616 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height85 mm
Depth73 mm
A9DE6616 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Operating altitude2000 m
A9DE6616 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

The integrated earth-leakage protection trips at 300 mA sensitivity, which is a common setting for final subcircuits where a 30 mA unit would cause nuisance tripping on longer cable runs or equipment with natural leakage. Breaking capacity is 4500 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1, which covers most residential and light commercial distribution boards in the UK and European markets. Limitation class 3 (energy-limiting) means it restricts let-through energy in a fault — useful for downstream coordination with less robust wiring or loads.

Tunnel terminals accept 1–16 mm² rigid or 1–10 mm² flexible cable; strip length 14 mm, tightening torque 2 N·m. IP20 on the body, IP40 inside the modular enclosure. The toggle provides local ON/OFF and fault indication. This is an outgoer device in the distribution board — not a main switch.

Frequently asked questions

What is the breaking capacity of A9DE6616?

4500 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1.

What earth-leakage sensitivity does A9DE6616 have?

300 mA, integrated into the RCBO unit.

Where can I buy A9DE6616 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
A9DE6616