Skip to main content
Schneider Electric A9DF7632 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DF7632 Acti9 iCV40 32A RCBO, 6kA, C-cur

MPNA9DF7632
Active

Schneider Electric Acti9 iCV40 RCBO, A9DF7632, 1P+N, 32 A, C-curve, 6 kA Icn, 300 mA earth-leakage, DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9DF7632 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A-SI (Super Immunised)
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationFault indication ON/OFF indication
A9DF7632 — Electrical Ratings
ParameterValue
Rated current (In)32 A
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability10000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DF7632 — Identification
ParameterValue
Product nameActi9 iCV40
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiCV40N
A9DF7632 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height85 mm
Depth73 mm
A9DF7632 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Operating altitude2000 m
A9DF7632 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

The Schneider Electric A9DF7632 is an Acti9 iCV40 RCBO — a combined overcurrent and earth-leakage protection device in a single 36 mm wide, 1P+N module. Breaking capacity is 6000 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1 — limitation class 3. That means it limits let-through energy enough to protect downstream wiring under fault conditions, not just clear the fault.

The 32 A rated current is the continuous load it can carry without tripping — size your circuit so the expected load stays under that. The 300 mA earth-leakage sensitivity is a general-purpose level for protection against fire risk from ground faults, not personnel protection (that needs 30 mA or lower).

Frequently asked questions

What is A9DF7632's listed depth (73 mm) on this component line?

The depth is 73 mm. That includes the toggle switch and terminal clearance — verify your enclosure depth to ensure the module fits without interference.

What is A9DF7632's listed range (Acti9) on this component line?

It belongs to the Schneider Electric Acti9 range, specifically the iCV40 series. Acti9 is the modular DIN-rail protection and control platform for distribution boards.

What compliance documentation does this brand provide for A9DF7632 (RoHS, REACH, UL, IEC)?

The A9DF7632 conforms to EN/IEC 61009-2-1 and IEC 60364 overvoltage category III. It carries VDE and EAC quality labels. For RoHS/REACH declarations, Schneider Electric publishes compliance documentation on their Schneider Electric Exchange portal — the product is within the Acti9 range which is generally RoHS compliant, but verify the specific declaration for your lot.

MPN