Schneider Electric A9DF8606 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DF8606 Acti9 iCV40 RCBO, 6 A, C-curve,

MPNA9DF8606
Active

Schneider Electric Acti9 iCV40 RCBO, 1P+N, 6 A, C-curve, 10 kA Icn at 230 V AC, 300 mA earth-leakage, thermal-magnetic trip, DIN-rail clip-on, IP20/IP40.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9DF8606 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A-SI (Super Immunised)
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationFault indication ON/OFF indication
A9DF8606 — Electrical Ratings
ParameterValue
Rated current (In)6 A
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DF8606 — Identification
ParameterValue
Product nameActi9 iCV40
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiCV40H
A9DF8606 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height85 mm
Depth73 mm
A9DF8606 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Operating altitude2000 m
A9DF8606 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

The Schneider Electric A9DF8606 is an Acti9 iCV40 residual-current circuit breaker with overcurrent protection (RCBO) — a single module that combines a 6 A thermal-magnetic MCB with a 300 mA earth-leakage detector. It protects final circuits against overload, short-circuit (C-curve, magnetic trip 5–10 × In), and ground faults, all in one 36 mm-wide, 1P+N package that clips onto a DIN rail. The C-curve means it holds through moderate inrush (motors, transformers, LED drivers) and trips fast on hard shorts.

The 300 mA earth-leakage threshold is a ground-fault level for fixed equipment. Thermal-magnetic trip means the bimetal handles sustained overloads (slow, heat-based) and the solenoid handles short-circuits (instantaneous above 5–10 × In).

Tunnel terminals accept 1–16 mm² rigid or 1–10 mm² flexible cable; tighten to 2 N·m.

The Acti9 family is Schneider's active residential and light-commercial distribution range.

Frequently asked questions

What is the breaking capacity of the A9DF8606?

The A9DF8606 has a breaking capacity of 10,000 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1.

MPN
A9DF8606