Skip to main content
Schneider Electric A9DF8625

Schneider Electric A9DF8625 Acti9 iCV40H RCBO, 25 A C-curve,

MPN A9DF8625
Active

Schneider Electric Acti9 iCV40H RCBO, A9DF8625, 25 A rated, C-curve, 10 kA Icn at 230 V AC, integrated 300 mA earth-leakage protection, thermal-magnetic trip, DIN-rail clip-on, 1P+N, 4 modules wide.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9DF8625 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9DF8625 additional specifications
ParameterValue
ColorWhite
Depth73 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9DF8625 is a 25 A RCBO from the Acti9 iCV40H series — a combined overcurrent and residual-current device in a single 36 mm wide (4-module) package. Integrated 300 mA earth-leakage protection covers ground-fault detection in the same unit, saving a DIN slot versus a separate RCCB. Mounts via clip-on to a standard DIN rail (EN 60715). Tunnel terminals accept 1 to 16 mm² rigid or 1 to 10 mm² flexible cable; tighten to 2 N·m. Stripping length is 14 mm.

Compliance documentation includes VDE and EAC quality labels. The RCBO is designed to EN/IEC 61009-2-1 (residual current operated circuit-breakers with integral overcurrent protection) and carries limitation class 3 for energy-limiting performance under fault conditions.

Integration into the distribution board

Occupies 4 modules (36 mm) on the DIN rail. The IP20 rating applies to the front of the device; IP40 applies when enclosed in a modular enclosure. Operating altitude is limited to 2000 m without derating. Rated for 50/60 Hz AC networks only. The thermal-magnetic trip unit provides both overload (thermal bimetal) and short-circuit (magnetic coil) protection. Electrical and mechanical durability are both rated at 20,000 cycles.

MPN
A9DF8625