Skip to main content
Schneider Electric A9DG3613 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DG3613 Acti9 iCV40 RCBO, 13 A, 30 mA, B

MPNA9DG3613
Active

Schneider Electric Acti9 iCV40 RCBO, 1P+N, 13 A, B curve, 30 mA earth leakage, 6 kA breaking capacity, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9DG3613 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication Fault indication
A9DG3613 — Electrical Ratings
ParameterValue
Rated current (In)13 A
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DG3613 — Identification
ParameterValue
Product nameActi9 iCV40
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiCV40N
A9DG3613 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height85 mm
Depth73 mm
A9DG3613 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Operating altitude2000 m
A9DG3613 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

The Schneider Electric A9DG3613 is an Acti9 iCV40 combined residual current circuit breaker with overcurrent protection (RCBO), rated 13 A with 30 mA earth-leakage sensitivity and a B tripping curve.

The 30 mA earth-leakage threshold provides personnel protection per IEC 60364 (additional protection against direct contact). Thermal-magnetic trip technology means the thermal bimetal handles overloads (time-delayed), while the solenoid handles short-circuits (instantaneous). The limitation class 3 rating indicates it limits let-through energy well — useful for downstream cable protection and selectivity with upstream devices.

Neutral is on the left (1P+N configuration). Tunnel terminals accept 1–16 mm² rigid or 1–10 mm² flexible cable; tighten to 2 N·m. Wire strip length 14 mm.

Frequently asked questions

What is the breaking capacity of A9DG3613?

The breaking capacity is 6000 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 61009-2-1.

What is the earth-leakage sensitivity of this RCBO?

The earth-leakage sensitivity is 30 mA, providing personnel protection.

Where can I buy A9DG3613?

The A9DG3613 is sourced and quoted to order against an RFQ through independent distribution, with availability and current pricing confirmed at quote time.

What standards does A9DG3613 comply with?

It complies with EN/IEC 61009-2-1 and carries VDE, EAC, and OVE quality labels.

MPN