A9DGA610 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)10 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication Fault indication
A9DGA610 — Electrical Ratings
ParameterValue
Rated current (In)10 A
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DGA610 — Identification
ParameterValue
Product nameActi9 iCV40
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiCV40N
A9DGA610 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height94 mm
Depth74 mm
A9DGA610 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Operating altitude2000 m
A9DGA610 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

The A9DGA610: Rated 10 A with a B-curve (magnetic trip between 3 and 5 x In) means it's sized for residential or light commercial final circuits — lighting, socket outlets — where inrush is low. Limitation class 3 (EN/IEC 61009-2-1) means it lets through limited energy under short-circuit — good for protecting downstream wiring and loads. Integrated earth-leakage protection at 10 mA sensitivity (the lowest standard threshold) makes this unit suitable for circuits requiring high personnel protection — think wet areas, construction-site sockets, or medical locations where a 30 mA device would be too slow. The thermal-magnetic trip unit handles both overload (thermal bimetal) and short-circuit (magnetic solenoid) in one package.

Tunnel-type terminals accept 1 to 16 mm² rigid or 1 to 10 mm² flexible cable; strip length 14 mm. Tightening torque 2 N·m top or bottom. The 9 mm connection pitch between phase and neutral matches the Acti9 modular system for busbar bridging.

Frequently asked questions

What is A9DGA610's breaking capacity and sensitivity?

The A9DGA610 has a breaking capacity of 6000 A Icn at 230 V AC (EN/IEC 61009-2-1) and an earth-leakage sensitivity of 10 mA.