Schneider Electric A9DGA616 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9DGA616 Acti9 iCV40 RCBO, 16 A, 30 mA, B

MPNA9DGA616
Active

Schneider Electric Acti9 iCV40, A9DGA616, RCBO, 1P+N, 16 A, B curve, 10 mA earth leakage, 6 kA Icn at 230 V AC.

$214.22Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9DGA616 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)10 mA
Earth-leakage protection class / typeType A
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication Fault indication
A9DGA616 — Electrical Ratings
ParameterValue
Rated current (In)16 A
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Overvoltage categoryIII conforming to IEC 60364
Device location in systemOutgoer
Electrical durability20000 cycles
Mechanical durability (operating cycles)20000 cycles
A9DGA616 — Identification
ParameterValue
Product nameActi9 iCV40
Product / component typeResidual current breaker with overcurrent protection (RCBO)
Product range / familyActi9
Device short nameiCV40N
A9DGA616 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals top or bottom 1...16 mm² rigid Tunnel type terminals top or bottom 1...10 mm² flexible
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque2 N.m top or bottom
Width36 mm
Height94 mm
Depth74 mm
A9DGA616 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Relative humidity95 % at 55 °C
Operating altitude2000 m
A9DGA616 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1

Product details

Rated 16 A with a B curve (magnetic trip 3–5 x In) and integrated 10 mA earth-leakage protection, it clears faults at 6 kA Icn per EN/IEC 61009-2-1. This is a 1P+N unit with neutral on the left, clip-on DIN rail mount, and IP20 finger-safe terminals.

The 10 mA sensitivity is the standout here — this is a high-sensitivity residual current trip, not the standard 30 mA. It's sized for circuits where even a small leakage to ground must be caught: wet environments, medical locations, or circuits supplying hand-held equipment where the extra protection is specified by code. The B curve (3–5 x In) means magnetic trip happens between 48 A and 80 A, fast enough for short circuits in residential or light commercial final circuits with resistive or modest inductive loads.

Deployment context

Clip-on DIN rail mount, 36 mm (4 x 9 mm pitches). Fits standard modular enclosures.

Current production per the manufacturer's lifecycle status.

MPN