Skip to main content
Schneider Electric A9F03204 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F03204 Acti9 iC60N MCB, 4 A, Curve B, 2

MPNA9F03204
Active

Schneider Electric Acti9 iC60N, A9F03204, miniature circuit breaker, 4 A, curve B, 2P, 50 kA Icu at 415 V AC, DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F03204 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameIC60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F03204 — Electrical
ParameterValue
Rated current [In]4 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)DC AC
Network frequency50/60 Hz
A9F03204 — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit4 x In +/- 20 %
Breaking capacity (Icu)50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F03204 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F03204 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F03204 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F03204 is an Acti9 iC60N miniature circuit breaker rated 4 A, curve B, 2-pole, with a breaking capacity of 50 kA Icu at 415 V AC.

Rated at 50 kA Icu across 12–415 V AC (50/60 Hz) per EN/IEC 60947-2, and 10 kA Icn at 400 V per EN/IEC 60898-1. That 50 kA figure means it safely interrupts high fault currents typical in industrial panel secondary distribution — no cascading upstream breakers needed on most sub-circuits. The dual standard certification (60947-2 for industrial, 60898-1 for residential/commercial) gives flexibility in specifying across different installation codes.

Occupies 4 x 9 mm pitches (36 mm width) on DIN rail, with a depth of 78.5 mm and height of 91 mm.

Frequently asked questions

What is the breaking capacity of A9F03204?

The A9F03204 has a breaking capacity of 50 kA Icu at 12–415 V AC per EN/IEC 60947-2, and 10 kA Icn at 400 V per EN/IEC 60898-1.

What is the rated current and curve of A9F03204?

Rated current is 4 A with a B curve (magnetic trip at 4 x In ±20 %), 2-pole, suitable for general distribution and resistive/light inductive loads.

What standards does A9F03204 comply with?

It complies with EN/IEC 60947-2 and EN/IEC 60898-1, covering both industrial and residential/commercial applications.

Where can I buy A9F03204?

The A9F03204 is sourced to order against an RFQ through independent distribution channels. Availability and pricing are confirmed at quote time — submit an RFQ for current terms.

MPN
A9F03204