Schneider Electric A9F03206 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F03206 Acti9 iC60N MCB, 6 A, 2P, Curve

MPNA9F03206
Obsolete

Schneider Electric Acti9 iC60N miniature circuit-breaker, A9F03206, 2P, 6 A, curve B, breaking capacity 36 kA Icu at 12-133 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F03206 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameIC60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F03206 — Electrical
ParameterValue
Rated current [In]6 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC DC
Network frequency50/60 Hz
A9F03206 — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit4 x In +/- 20 %
Breaking capacity (Icu)36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F03206 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F03206 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F03206 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F03206 is a 2-pole miniature circuit-breaker from the Acti9 iC60N family, rated 6 A with a B-curve trip characteristic (magnetic trip at 4 x In ±20 %). The 36 kA Icu at 12–133 V AC (EN/IEC 60947-2) tells you it can safely interrupt a fault up to that level without welding contacts or cascading upstream; at 220–240 V AC that drops to 20 kA Icu, and at 380–415 V AC to 10 kA Icu. Dual-certified to both standards means it can be specified in industrial panels (60947-2) or final-distribution boards (60898-1) — the same part, different paperwork.

Deployment context

IP20 finger-safe front; the terminals accept up to 25 mm² rigid or 16 mm² flexible, with a 14 mm strip length and 2 N·m torque.

Pollution degree 3 (conforms to 60947-2) rates it for conductive environments — typical in control panels. Overvoltage category IV, so it can be installed at the service entrance. No separate RoHS/REACH statement in the evidence, but Schneider Electric standard compliance documentation is available on request with the RFQ.

Frequently asked questions

What is the breaking capacity of A9F03206?

36 kA Icu at 12–133 V AC, 20 kA Icu at 220–240 V AC, 10 kA Icu at 380–415 V AC, and 6 kA Icn at 400 V AC per EN/IEC 60898-1.

What compliance documentation does A9F03206 carry?

Certified to EN/IEC 60947-2 and EN/IEC 60898-1, pollution degree 3, tropicalisation class 2, overvoltage category IV. Standard Schneider Electric compliance documentation is available on request.

MPN