Skip to main content
Schneider Electric A9F03206

Schneider Electric A9F03206 Acti9 iC60N MCB, 6 A, 2P, Curve

MPN A9F03206
Obsolete

Schneider Electric Acti9 iC60N miniature circuit-breaker, A9F03206, 2P, 6 A, curve B, breaking capacity 36 kA Icu at 12-133 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03206 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F03206 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F03206 is a 2-pole miniature circuit-breaker from the Acti9 iC60N family, rated 6 A with a B-curve trip characteristic (magnetic trip at 4 x In ±20 %). The 36 kA Icu at 12–133 V AC (EN/IEC 60947-2) tells you it can safely interrupt a fault up to that level without welding contacts or cascading upstream; at 220–240 V AC that drops to 20 kA Icu, and at 380–415 V AC to 10 kA Icu. Dual-certified to both standards means it can be specified in industrial panels (60947-2) or final-distribution boards (60898-1) — the same part, different paperwork.

Deployment context

IP20 finger-safe front; the terminals accept up to 25 mm² rigid or 16 mm² flexible, with a 14 mm strip length and 2 N·m torque.

Pollution degree 3 (conforms to 60947-2) rates it for conductive environments — typical in control panels. Overvoltage category IV, so it can be installed at the service entrance. No separate RoHS/REACH statement in the evidence, but Schneider Electric standard compliance documentation is available on request with the RFQ.

MPN
A9F03206