Schneider Electric A9F03213 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F03213 Acti9 iC60N MCB, 13A, 2P, B-Curv

MPNA9F03213
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 13 A, 2P, B-curve, 36 kA breaking capacity, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F03213 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameIC60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F03213 — Electrical
ParameterValue
Rated current [In]13 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC DC
Network frequency50/60 Hz
A9F03213 — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit4 x In +/- 20 %
Breaking capacity (Icu)36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F03213 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F03213 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F03213 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F03213 is a Schneider Electric Acti9 iC60N miniature circuit breaker (MCB) — a 2-pole, 13 A, B-curve unit rated for distribution in AC and DC networks. It is a thermal-magnetic trip device with a 36 kA Icu breaking capacity at 12…133 V AC, 20 kA at 220…240 V AC, and 10 kA at 380…415 V AC (EN/IEC 60947-2), plus 10 kA Icn at 400 V (EN/IEC 60898-1). That dual-standard rating means it is certified for both industrial (60947-2) and residential/commercial (60898-1) installations — the 36 kA figure applies at the low-voltage end typical of control transformers, while the 10 kA at 400 V covers the common three-phase distribution bus.

Double terminals top and bottom accept 1…25 mm² rigid or 1…16 mm² flexible cable; stripping length is 14 mm, torque to 2 N·m.

Frequently asked questions

What is A9F03213's breaking capacity at 400 V AC?

At 400 V AC 50/60 Hz, the A9F03213 is rated 10 kA Icn per EN/IEC 60898-1 and 10 kA Icu per EN/IEC 60947-2.

Where can I buy A9F03213?

The A9F03213 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN