Skip to main content
Schneider Electric A9F03302

Schneider Electric A9F03302 Acti9 iC60N MCB, 2 A, Curve B, 3

MPN A9F03302
Obsolete

Schneider Electric Acti9 iC60N, miniature circuit breaker, 3P, 2 A, curve B, 50 kA breaking capacity at 240 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03302 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F03302 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F03302 is a 3-pole Acti9 iC60N miniature circuit breaker rated at 2 A with a B-curve trip characteristic. This dual-standard certification (60947-2 for industrial and 60898-1 for residential/commercial) gives flexibility in panel design across both domains. The 2 A rating and B-curve (magnetic trip at 4 x In +/- 20%) suit circuits with resistive or lightly inductive loads where nuisance tripping from inrush is a concern — think lighting strings, control transformers, or small power supplies in a sub-distribution board.

The 54 mm width across 3 poles fits 6 modules of 9 mm pitch — standard for a 3-pole MCB in a distribution board. Depth is 78.5 mm, height 91 mm. The toggle control and trip indicator give clear local status.

Overvoltage category IV and pollution degree 3 ratings mean the breaker is rated for the highest surge exposure at the service entrance and can tolerate conductive dust and humidity up to 95% at 55 °C — a solid fit for industrial panels near the main incomer.

MPN
A9F03302