Schneider Electric A9F03332

A9F03332 Acti9 iC60 3P 32A Curve B MCB, 36 kA Icu

MPN A9F03332
Active

Schneider Electric Acti9 iC60, miniature circuit-breaker, 3P, 32 A, curve B, 36 kA Icu at 12-133 V AC, DIN rail mount, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03332 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9F03332 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F03332 is a 3-pole (3P) Acti9 iC60 miniature circuit-breaker rated 32 A with a B-curve trip characteristic — magnetic tripping occurs at 4 x In (±20%), so it clears short-circuits fast on resistive or general-purpose loads where inrush isn't high. The 36 kA Icu at 12–133 V AC is the maximum interrupting capacity under EN/IEC 60947-2; at 220–240 V AC it still holds 20 kA Icu, and at 380–415 V AC it delivers 10 kA Icu. That's enough for most distribution panels fed by a transformer of moderate kVA — the SCCR headroom is there for the common 400 V three-phase bus. The 10 kA Icn at 400 V under EN/IEC 60898-1 is the standard domestic/commercial rating, so this breaker fits both industrial (60947-2) and installation (60898-1) applications. Mounts on a DIN rail (6 x 9 mm pitches = 54 mm wide, 91 mm high, 78.5 mm deep), so it occupies three standard module spaces in the enclosure. The thermal-magnetic trip unit is non-interchangeable — you buy the rating, that's what protects the circuit.

Certified to both EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/commercial) — dual-standard approval means it's accepted in panel builds across Europe and many other markets that harmonize with IEC. Suitable for isolation per both standards, with a contact position indicator and trip indicator for visual status. IP20 finger-safe terminals. The double-terminal design accepts 1–35 mm² rigid or 1–25 mm² flexible on top or bottom — enough for the 32 A feed and downstream load wiring. Earth-leakage protection is handled by a separate block (Vigi iC60), not integrated.

MPN