Skip to main content
Schneider Electric A9F03332 — Miniature Circuit Breakers (MCB)

A9F03332 Acti9 iC60 3P 32A Curve B MCB, 36 kA Icu

MPNA9F03332
Active

Schneider Electric Acti9 iC60, miniature circuit-breaker, 3P, 32 A, curve B, 36 kA Icu at 12-133 V AC, DIN rail mount, white.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F03332 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F03332 — Ratings
ParameterValue
Rated current (In)32 A
Poles configuration3P
Number of protected poles3
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F03332 — Protection
ParameterValue
Curve codeB
Trip unit technologyThermal-magnetic
Magnetic tripping limit4 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F03332 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6
A9F03332 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F03332 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F03332 is a 3-pole (3P) Acti9 iC60 miniature circuit-breaker rated 32 A with a B-curve trip characteristic — magnetic tripping occurs at 4 x In (±20%), so it clears short-circuits fast on resistive or general-purpose loads where inrush isn't high. The 36 kA Icu at 12–133 V AC is the maximum interrupting capacity under EN/IEC 60947-2; at 220–240 V AC it still holds 20 kA Icu, and at 380–415 V AC it delivers 10 kA Icu. That's enough for most distribution panels fed by a transformer of moderate kVA — the SCCR headroom is there for the common 400 V three-phase bus. The 10 kA Icn at 400 V under EN/IEC 60898-1 is the standard domestic/commercial rating, so this breaker fits both industrial (60947-2) and installation (60898-1) applications. Mounts on a DIN rail (6 x 9 mm pitches = 54 mm wide, 91 mm high, 78.5 mm deep), so it occupies three standard module spaces in the enclosure. The thermal-magnetic trip unit is non-interchangeable — you buy the rating, that's what protects the circuit.

Certified to both EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/commercial) — dual-standard approval means it's accepted in panel builds across Europe and many other markets that harmonize with IEC. Suitable for isolation per both standards, with a contact position indicator and trip indicator for visual status. IP20 finger-safe terminals. The double-terminal design accepts 1–35 mm² rigid or 1–25 mm² flexible on top or bottom — enough for the 32 A feed and downstream load wiring. Earth-leakage protection is handled by a separate block (Vigi iC60), not integrated.

Frequently asked questions