Schneider Electric A9F03350 Acti9 iC60N MCB, 50 A, 3P, B Cur

MPN A9F03350
Active

Schneider Electric Acti9 iC60N range, A9F03350, 3-pole miniature circuit breaker, 50 A rated, B-curve, thermal-magnetic trip, 36 kA Icu at 12-133 V AC, DIN-rail mount, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03350 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F03350 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F03350 is a 3-pole Acti9 iC60N miniature circuit breaker rated at 50 A with a B-curve thermal-magnetic trip unit. Breaking capacity is 36 kA Icu at 12-133 V AC, 20 kA Icu at 220-240 V AC, 10 kA Icu at 380-415 V AC, and 6 kA Icu at 440 V AC per EN/IEC 60947-2. Under the 60898-1 standard it carries a 10 kA Icn at 400 V AC.

The double-terminal top and bottom accepts 1-35 mm² rigid or 1-25 mm² flexible, with a stripping length of 14 mm and a tightening torque of 3.5 N.m. That 35 mm² capacity on a 50 A breaker means you can land the incoming feeder without a separate terminal block, saving a row of DIN rail. Pollution degree 3 per EN/IEC 60947-2 and overvoltage category IV — this breaker is rated for the harsh electrical environment of a main distribution board where transient overvoltages are common, not just a clean subpanel. IP20 finger-safe terminals are standard for enclosed panels.