Skip to main content
Schneider Electric A9F03432

A9F03432 Acti9 iC60N MCB, 32 A, 4P, Curve B, 36 kA

MPN A9F03432
Active

Schneider Electric Acti9 iC60N, A9F03432, miniature circuit-breaker, 4P, 32 A, curve B, breaking capacity 36 kA Icu at 12…133 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03432 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F03432 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F03432 is an Acti9 iC60N miniature circuit-breaker rated 32 A with a B-curve trip characteristic, 4 poles protected, and a breaking capacity of 36 kA Icu at 12…133 V AC (EN/IEC 60947-2). It is a current-production part — lifecycle stage is current — sourced through independent distribution channels.

The 4-pole (4P) construction switches all live conductors, suitable for three-phase plus neutral circuits. Breaking capacity is the key coordination figure: 36 kA Icu at 12…133 V AC, 20 kA at 220…240 V, 10 kA at 380…415 V, and 6 kA at 440 V (EN/IEC 60947-2). It also carries a 10 kA Icn at 400 V under EN/IEC 60898-1.

Deployment context

Snap-on DIN rail mounting (9 mm pitch, 8 pitches wide — 72 mm) fits standard panel enclosures. Double terminals top and bottom accept 1…35 mm² rigid or 1…25 mm² flexible, with a tightening torque of 3.5 N·m. The IP20 finger-safe front allows panel-side handling; the trip indicator gives local visual status without opening the door.

Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household / similar) — so it qualifies for both distribution boards and industrial panelboards. Pollution degree 3, overvoltage category IV, suitability for isolation marked on the device.

MPN
A9F03432