Schneider Electric A9F03463 Acti9 iC60N MCB, 63 A, 4P, Curve

MPN A9F03463
Active

Schneider Electric Acti9 iC60N, A9F03463, miniature circuit breaker, 4P, 63 A, curve B, 36 kA breaking capacity at 12-133 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F03463 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9F03463 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F03463 is an Acti9 iC60N miniature circuit breaker — 4 poles, 63 A rated current, curve B, thermal-magnetic trip. It's rated for distribution duty in AC and DC networks, with a 36 kA Icu at 12–133 V AC and 10 kA Icu at 380–415 V AC per EN/IEC 60947-2. The 6 kA Icn at 400 V per EN/IEC 60898-1 covers the standard residential/commercial coordination.

The 36 kA Icu at 12–133 V AC covers low-voltage distribution where fault current can spike — a panel fed from a 100 kVA transformer on a 120 V secondary, for example. At 220–240 V it still holds 20 kA Icu, and at 380–415 V it's 10 kA Icu. The 6 kA Icn at 400 V per EN/IEC 60898-1 is the standard domestic coordination. The 4 poles are all protected — no solid neutral. That matters for three-phase plus neutral distribution where you need overcurrent protection on every phase and the neutral. The thermal-magnetic trip unit gives you a fixed thermal curve (B) and a magnetic threshold at 4 x In. Curve B is the least tolerant of inrush among standard curves, so it's the right choice for circuits with predominantly resistive loads or long cable runs where selectivity with downstream MCBs is the goal. The trip indicator and contact position indicator give visual confirmation of state, which saves time during fault-finding or LOTO procedures.

Snaps onto a DIN rail — 9 mm pitch, 8 modules wide (72 mm). That's standard for the Acti9 range; it'll fit any 35 mm rail in a distribution board. Strip length 14 mm. The IP20 finger-safe front is fine for enclosed panels; not rated for washdown. Earth-leakage protection is handled by a separate block — the MCB itself doesn't include RCD functionality. If your circuit needs 30 mA or 300 mA residual current protection, you add a Vigi iC60 or iID block downstream. The MCB's 95 % humidity at 55 °C and pollution degree 3 rating mean it's comfortable in non-conditioned electrical rooms.