Skip to main content
Schneider Electric A9F04150

Schneider Electric A9F04150 Acti9 iC60N MCB, 50 A, C Curve,

MPN A9F04150
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 1P, 50 A, C curve, 36 kA Icu at 12-60 VAC, DIN rail mount, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F04150 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F04150 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F04150 is an Acti9 iC60N miniature circuit breaker — 1 pole, 50 A rated current, C curve, thermal-magnetic trip. It carries dual certification to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/commercial), so it qualifies for both distribution panels and machine control cubicles. The 18 mm width per pole means it snaps onto DIN rail at two 9 mm pitches, leaving the adjacent slots free for other breakers or accessories.

Breaking capacity varies by voltage and standard. Under EN/IEC 60947-2 the Icu is 36 kA at 12-60 VAC, 20 kA at 100-133 VAC, and 10 kA at 220-240 VAC. On the DC side it delivers 15 kA at 12-60 VDC and 10 kA at 60-72 VDC. Under EN/IEC 60898-1 the Icn is 6000 A at 230 VAC. That 36 kA figure at low AC voltages gives headroom for high-fault panels fed from large transformers — useful when coordinating downstream branch breakers.

Terminal and wiring

Double terminals top and bottom accept 1-35 mm² rigid or 1-25 mm² flexible. The IP20 finger-safe terminals suit enclosed panel mounting.

Rated for 10,000 electrical and 20,000 mechanical cycles. It is suitable for isolation per both standards — the contact position indicator shows open/closed status visibly on the toggle. The C curve magnetic trip fires at 8 x In ±20%, so it handles motor inrush up to around 400 A peak without nuisance tripping on moderate starts.

MPN