Schneider Electric A9F04225

Schneider Electric A9F04225 Acti9 iC60N MCB, 25 A, 2P, C-Cur

MPN A9F04225
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 25 A, 2P, C-curve, 36 kA Icu at 12-133 V AC, DIN rail mount, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F04225 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F04225 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F04225 is an Acti9 iC60N miniature circuit breaker, rated 25 A, 2 poles, with a C-curve trip characteristic. It carries a 36 kA Icu breaking capacity at 12-133 V AC (per EN/IEC 60947-2) and a 10 kA Icn at 400 V AC (per EN/IEC 60898-1), making it suitable for distribution panel final circuits in commercial and light industrial builds.

The 25 A C-curve means the magnetic trip activates between 5 and 10 times rated current (8 x In +/-20 % per spec), so it handles moderate inrush from motorized or fluorescent loads without nuisance tripping. Thermal-magnetic trip technology means bimetal for overload, solenoid for short-circuit — no electronics to fail. Overvoltage category IV and pollution degree 3 mean it's rated for the mains entrance of an installation — not just downstream sub-distribution. The IP20 finger-safe terminals suit enclosed panel mounting, not wet or dusty environments.

Width is 36 mm (4 x 9 mm pitches), height 91 mm, depth 78.5 mm. Snaps onto standard DIN rail. The double terminals accept 1-25 mm² rigid or 1-16 mm² flexible, with a 2 N.m tightening torque and 14 mm strip length. Trip indicator shows local status; toggle control with contact position indicator for isolation verification (suitability for isolation confirmed per both standards).

MPN