Skip to main content
Schneider Electric A9F04301

A9F04301 Acti9 iC60 Miniature Circuit-Breaker, 1 A, C Curve,

MPN A9F04301
Active

Schneider Electric Acti9 iC60 miniature circuit-breaker, A9F04301, 1 A rated current, C curve, 3 poles, 50 kA Icu at 415 V AC, DIN rail mount, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F04301 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F04301 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F04301 is a Schneider Electric Acti9 iC60 miniature circuit-breaker rated at 1 A with a C curve, three poles, and a breaking capacity of 50 kA Icu at 415 V AC. It's a thermal-magnetic trip unit designed for distribution circuits on DIN rail, covering both AC and DC networks at 50/60 Hz.

The 1 A rating with C curve (magnetic trip at 8 x In ±20%) means this breaker protects small loads like control transformers or signal circuits where inrush is moderate — not motor feeders. The 10 kA Icn at 400 V (per EN/IEC 60898-1) is the domestic/commercial rating — the higher Icu figure is the industrial one that matters for distribution boards with large upstream transformers. The IP20 finger-safe terminals are standard for enclosed gear; no washdown rating here.

Snaps onto DIN rail, 54 mm wide (6 x 9 mm pitches), 91 mm tall, 78.5 mm deep. Double terminals top and bottom accept 1–25 mm² rigid or 1–16 mm² flexible — strip 14 mm, torque to 2 N.m. The toggle handle and trip indicator give local status; a separate earth-leakage block can be added alongside.

MPN