Schneider Electric A9F04410 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F04410 Acti9 iC60N MCB, 10 A, C-Curve,

MPNA9F04410
Active

Schneider Electric Acti9 iC60N, A9F04410, miniature circuit-breaker, 4P, 10 A, C-curve, 36 kA Icu at 12-133 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F04410 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F04410 — Ratings
ParameterValue
Rated current (In)10 A
Poles configuration4P
Number of protected poles4
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F04410 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F04410 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8

Environmental

A9F04410 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F04410 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F04410 is a 10 A, 4-pole miniature circuit-breaker from the Schneider Electric Acti9 iC60N family. It is a thermal-magnetic MCB (trip unit technology: thermal-magnetic) with a C-curve (magnetic tripping limit 8 x In +/- 20 %), rated for both AC and DC networks at 50/60 Hz. The 36 kA Icu at 12-133 V AC (EN/IEC 60947-2) and 10 kA Icn at 400 V AC (EN/IEC 60898-1) tell you this breaker handles high short-circuit currents in a distribution panel — it's not a branch-circuit-only device. The dual-standard compliance (EN/IEC 60947-2 for industrial, EN/IEC 60898-1 for residential/commercial) means it qualifies for either type of installation, giving flexibility on the BOM.

Mounts on DIN rail (mounting support: DIN rail), occupies 8 x 9 mm pitches (72 mm width) — standard 4-pole MCB footprint. Depth is 78.5 mm, height 91 mm. The double terminal accepts 1-25 mm² rigid or 1-16 mm² flexible, top or bottom. Tightening torque 2 N.m. Strip length 14 mm for both top and bottom connections. IP20 (conforms to IEC 60529) — suitable for enclosed distribution boards only, not washdown areas.

Rated current 10 A (In) — this is the continuous load it can carry without tripping. C-curve (magnetic trip at 8 x In, +/- 20 %) means it holds through motor inrush up to about 80 A before the magnetic coil trips; good for lighting panels or mixed loads with moderate starting currents, not for heavy motor starts (that would want a D-curve). Breaking capacity: 36 kA Icu at 12-133 V AC, 20 kA at 220-240 V AC, 10 kA at 380-415 V AC, 6 kA at 440 V AC (all per EN/IEC 60947-2). The 10 kA Icn at 400 V AC (EN/IEC 60898-1) is the standard residential/commercial rating. The 36 kA figure at lower voltages means this breaker can be used on 110 V panels with high fault current — useful in industrial control panels fed from a 110 V control transformer with high SCCR. Overvoltage category IV — for main distribution boards. Suitability for isolation: yes, per both standards, so it can be used as a disconnecting means.

Frequently asked questions

What is the closest alternative to A9F04410 in the Acti9 family?

Within the same Acti9 iC60 range, the closest sibling is the same 10 A, 4P, C-curve MCB with a different breaking capacity or a different curve (B or D). The physical footprint (DIN rail, 72 mm width) and terminal specs are identical; the difference is the short-circuit rating or trip curve. If you need the same 10 A, 4P, C-curve with a different breaking capacity, look at the iC60H or iC60L variants — they share the same dimensions and connections.