Skip to main content
Schneider Electric A9F04603 — 1-Pole MCB (DIN Rail)

Schneider Electric A9F04603 Acti9 iC60 MCB, 3 A C-Curve 1P+N

MPNA9F04603
Active

Schneider Electric Acti9 iC60 miniature circuit breaker, A9F04603, 3 A rated current, C-curve, 1P+N poles, 50 kA Icu breaking capacity, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F04603 — Identification
ParameterValue
Product nameActi9 iC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short nameIC60N
Poles description1P + N
Number of protected poles1
Device applicationDistribution
A9F04603 — Electrical & Protection
ParameterValue
Rated current (In)3 A
Tripping curve codeC
Magnetic tripping limit8 x In +/- 20 %
Breaking capacity (Icu / AIR)50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9F04603 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Mounting supportDIN rail
Width36 mm
Height91 mm
Depth78.5 mm
Tightening torque (by circuit)2 N.m top or bottom
A9F04603 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
A9F04603 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2 EN/IEC 60898-1
A9F04603 — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-2

Product details

It protects a single pole plus neutral (1P+N) in distribution boards, with a breaking capacity of 50 kA Icu at 240 V AC per IEC 60947-2 and 6000 A Icn at 230 V per IEC 60898-1.

Snaps onto a 36 mm-wide DIN rail — 4 x 9 mm pitches — and occupies a single module width. Double terminals at top and bottom accept 1 to 25 mm² rigid or 1 to 16 mm² flexible cable; strip length is 14 mm and tighten to 2 N.m. IP20 rated, so it lives inside a closed panel, not on the washdown floor.

Frequently asked questions

What is the breaking capacity of A9F04603?

50 kA Icu at 240 V AC under IEC 60947-2, and 6000 A Icn at 230 V under IEC 60898-1 — sufficient for most distribution board fault levels.

Where can I buy A9F04603?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN
A9F04603