Skip to main content
Schneider Electric A9F04610

Schneider Electric A9F04610 Acti9 iC60N MCB, 10 A, C-Curve,

MPN A9F04610
Active

Schneider Electric Acti9 iC60N, A9F04610, miniature circuit breaker, 10 A, C-curve, 1P+N, 36 kA breaking capacity at 12-60 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F04610 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F04610 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F04610 is an Acti9 iC60N miniature circuit breaker (MCB) rated 10 A with a C-curve magnetic trip characteristic (8 x In +/- 20 %), in a 1P+N pole configuration. The 1P+N format protects one phase and switches the neutral without protecting it, common in single-phase final distribution circuits. Breaking capacity is the key fit parameter here: 36 kA Icu at 12-60 V AC, 20 kA at 100-133 V AC, and 10 kA at 220-240 V AC per EN/IEC 60947-2. Under the domestic-standard EN/IEC 60898-1 it carries 6000 A Icn at 230 V AC. The dual rating lets you specify it under either standard depending on the local wiring code. Thermal-magnetic trip unit technology gives two-stage protection: the thermal bimetal handles sustained overloads (e.g., a stalled fan motor drawing 13 A on a 10 A circuit), while the magnetic coil clears short-circuits instantly. The 8 x In magnetic threshold (80 A nominal) is typical for C-curve — high enough to avoid nuisance tripping on capacitor inrush or motor starting, low enough to clear a bolted fault.

Mounts on DIN rail and occupies 4 x 9 mm pitches (36 mm wide), 91 mm tall, 78.5 mm deep — standard single-module width for a 1P+N MCB. The toggle control with trip indicator gives local visual status — white housing with a red flag visible when tripped. Neutral position is left; suitable for isolation per both EN/IEC 60898-1 and EN/IEC 60947-2, meaning you can safely lock it off for downstream work. Earth-leakage protection requires a separate block (Vigi iC60), not integrated.

MPN