Skip to main content
Schneider Electric A9F04620

Schneider Electric A9F04620 Acti9 iC60N MCB, 20 A, 1P+N, C-C

MPN A9F04620
Active

Schneider Electric Acti9 iC60N, A9F04620, miniature circuit breaker, 20 A, 1P+N, C-curve, 36 kA breaking capacity, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F04620 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F04620 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F04620 is an Acti9 iC60N miniature circuit breaker rated 20 A, 1P+N, with a C-curve. The 1P+N configuration protects one phase and switches the neutral, which is common in single-phase final distribution circuits.

This breaker carries dual certification: EN/IEC 60898-1 for household-type installations and EN/IEC 60947-2 for industrial applications. The breaking capacity depends on the voltage — 36 kA Icu at 12-60 V AC, 20 kA Icu at 100-133 V AC, and 10 kA Icu at 220-240 V AC under the 60947-2 standard. Under the 60898-1 standard it's rated 6000 A Icn at 230 V AC. That 10 kA at 240 V is what matters for most North American and European single-phase panels — it's enough for typical service entrance fault levels.

Width is 36 mm (4 x 9 mm pitches), height 91 mm, depth 78.5 mm. That's a standard 2-module footprint for a 1P+N breaker — no surprises when laying out a panel. Wire stripping length is 14 mm.

MPN