A9F04632 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F04632 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F04632 is a 32 A miniature circuit breaker from the Acti9 iC60N series, configured as 1P+N with a C-curve trip characteristic. It protects a single pole and switches the neutral, with the neutral on the left side of the unit. Rated 32 A at 50/60 Hz, this MCB is sized for general-purpose distribution circuits feeding lighting, socket outlets, and small loads. Breaking capacity is 36 kA Icu at 12…60 V AC, 20 kA at 100…133 V AC, and 10 kA at 220…240 V AC per EN/IEC 60947-2. For domestic-style installations it carries a 6000 A Icn at 230 V per EN/IEC 60898-1. That dual-rated standard coverage (60947-2 for industrial panels, 60898-1 for residential/commercial boards) gives flexibility in specifying the same part across both worlds.

At 36 mm wide (4 x 9 mm pitches) and 91 mm tall, it occupies a single modular slot plus neutral space in a distribution board. Terminals accept 1…35 mm² rigid or 1…25 mm² flexible wire, with a strip length of 14 mm and tightening torque of 3.5 N·m. The double-terminal design (top and bottom) allows looping through for daisy-chaining downstream loads without a separate junction. IP20 finger-safe protection suits enclosed panel mounting.

This is a widely specified MCB for European and IEC-based distribution boards.

Overvoltage category IV rating means it is suitable for installation at the origin of the installation (utility-side interface).

MPN
A9F04632