Schneider Electric A9F04701 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F04701 Acti9 iC60N MCB, 1 A C-Curve, 3P

MPNA9F04701
Active

Schneider Electric Acti9 iC60N, A9F04701, miniature circuit breaker, 1 A rated current, C-curve, 3 poles + neutral, 50 kA breaking capacity, DIN rail mount, thermal-magnetic trip.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F04701 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F04701 — Ratings
ParameterValue
Rated current (In)1 A
Poles configuration3P + N
Number of protected poles3
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F04701 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F04701 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8

Environmental

A9F04701 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F04701 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F04701 is an Acti9 iC60N miniature circuit breaker — 1 A rated, C-curve, 3 poles plus neutral, thermal-magnetic trip unit. It carries a 50 kA breaking capacity (Icu) at 220…240 V AC, dropping to 25 kA at 440 V AC, and 6 kA Icn per EN/IEC 60898-1 at 400 V. That dual standard (EN/IEC 60947-2 and 60898-1) means it qualifies for both industrial panel protection and building distribution — the 60947-2 rating is what matters for the SCCR declaration on a machine nameplate.

Snaps onto DIN rail, occupies 8 x 9 mm pitches (72 mm wide). The 78.5 mm depth leaves clearance in a standard 100 mm enclosure — no tight squeeze for the gland plate. Wire strip to 14 mm. Neutral is fixed left; the toggle gives local indication plus a trip flag.

Frequently asked questions

Where can I buy A9F04701 and get a price?

The A9F04701 is sourced to order against an RFQ through independent distribution. Submit a request with your quantity and target delivery window; availability and current pricing are confirmed at quote time.

What is the breaking capacity of A9F04701?

The A9F04701 delivers 50 kA Icu at 220…240 V AC and 380…415 V AC per EN/IEC 60947-2, 25 kA Icu at 440 V AC, and 6 kA Icn at 400 V AC per EN/IEC 60898-1. That dual rating covers both industrial panel SCCR and building-distribution fault levels.

What does the C-curve magnetic trip mean on A9F04701?

The C-curve trips magnetically at 8 x In ±20 % — that is 8 A to 9.6 A for this 1 A breaker. It is the standard choice for general-purpose distribution loads where inrush is moderate (lighting, small transformers, control circuits), not high-inrush motor starts.

MPN
A9F04701