Skip to main content
Schneider Electric A9F04706

A9F04706 Acti9 iC60 MCB, 6 A, Curve C, 3P+N, 36 kA

MPN A9F04706
Active

Schneider Electric Acti9 iC60N miniature circuit breaker, A9F04706, 6 A rated, C-curve, 3P+N, 36 kA Icu at 133 V AC, DIN rail mount, thermal-magnetic trip, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F04706 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F04706 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F04706 is an Acti9 iC60 miniature circuit breaker — a 6 A, C-curve, 3P+N unit built for distribution panels. It sits on a standard DIN rail, occupying 8 x 9 mm pitches (72 mm wide), with a depth of 78.5 mm and height of 91 mm. That footprint fits neatly into a crowded enclosure; the toggle and trip indicator are visible through the door.

The breaking capacity tells the real story: 36 kA Icu at 12–133 V AC, 20 kA at 220–240 V, 10 kA at 380–415 V, and 6 kA at 440 V AC. That's enough SCCR headroom for most panelboards fed from a transformer; the 6000 A Icn at 400 V (EN/IEC 60898-1) is the domestic-application ceiling. Dual-certified to EN/IEC 60947-2 and 60898-1, so it qualifies as both an industrial circuit breaker and a domestic MCB — useful when a single BOM covers both standards.

Integration notes

MPN
A9F04706