Schneider Electric A9F04750

Schneider Electric A9F04750 Acti9 iC60N MCB, 50 A, 3P+N, Cur

MPN A9F04750
Active

Schneider Electric Acti9 iC60N miniature circuit breaker, A9F04750, 50 A rated current, 3P+N poles, curve C, 36 kA breaking capacity at 12-133 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F04750 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F04750 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F04750 is an Acti9 iC60N miniature circuit breaker rated 50 A, 3P+N, curve C. Curve C trips magnetically at 8 x In +/- 20 %. Breaking capacity is the headline: 36 kA Icu at 12-133 V AC, 20 kA at 220-240 V, 10 kA at 380-415 V, and 6 kA at 440 V (all per EN/IEC 60947-2). The Icn rating under EN/IEC 60898-1 is 6000 A at 400 V. The higher 36 kA figure applies only at lower voltages (12-133 V), so don't misread it as the 400 V capability. Thermal-magnetic trip unit, no electronics to fail. Suitable for isolation per both standards — the contact position indicator shows open/closed state visibly.

Deployment context

Designed for DIN-rail mounting in commercial and industrial distribution boards — the 3P+N format with neutral left is standard for single-phase and three-phase subdistributions where you need to break all poles. The 50 A rating and curve C suit mixed loads: lighting, small motor groups, socket outlets, and general power distribution. Earth-leakage protection requires a separate vigi block (not included), so plan for that if the circuit needs RCD protection.