Schneider Electric A9F04750 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F04750 Acti9 iC60N MCB, 50 A, 3P+N, Cur

MPNA9F04750
Active

Schneider Electric Acti9 iC60N miniature circuit breaker, A9F04750, 50 A rated current, 3P+N poles, curve C, 36 kA breaking capacity at 12-133 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F04750 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F04750 — Ratings
ParameterValue
Rated current (In)50 A
Poles configuration3P + N
Number of protected poles3
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F04750 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F04750 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8

Environmental

A9F04750 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F04750 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F04750 is an Acti9 iC60N miniature circuit breaker rated 50 A, 3P+N, curve C. Curve C trips magnetically at 8 x In +/- 20 %. Breaking capacity is the headline: 36 kA Icu at 12-133 V AC, 20 kA at 220-240 V, 10 kA at 380-415 V, and 6 kA at 440 V (all per EN/IEC 60947-2). The Icn rating under EN/IEC 60898-1 is 6000 A at 400 V. The higher 36 kA figure applies only at lower voltages (12-133 V), so don't misread it as the 400 V capability. Thermal-magnetic trip unit, no electronics to fail. Suitable for isolation per both standards — the contact position indicator shows open/closed state visibly.

Deployment context

Designed for DIN-rail mounting in commercial and industrial distribution boards — the 3P+N format with neutral left is standard for single-phase and three-phase subdistributions where you need to break all poles. The 50 A rating and curve C suit mixed loads: lighting, small motor groups, socket outlets, and general power distribution. Earth-leakage protection requires a separate vigi block (not included), so plan for that if the circuit needs RCD protection.

Frequently asked questions

What is A9F04750's breaking capacity at 400 V?

At 380-415 V AC the Icu per EN/IEC 60947-2 is 10 kA. The Icn per EN/IEC 60898-1 at 400 V is 6000 A. The 36 kA figure applies only at 12-133 V AC, not at 400 V.

MPN
A9F04750