Skip to main content
Schneider Electric A9F05104 — 1-Pole MCB (DIN Rail)

A9F05104 Acti9 iC60 MCB, D Curve 4 A, 1P, 50 kA

MPNA9F05104
Active

Schneider Electric Acti9 iC60 miniature circuit breaker, A9F05104, 1P, D curve, 4 A rated current, 50 kA breaking capacity at 240 V AC, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F05104 — Identification
ParameterValue
Product nameActi9 iC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short nameIC60N
Poles description1P
Number of protected poles1
Device applicationDistribution

Electrical & Protection

A9F05104 — Electrical & Protection
ParameterValue
Rated current (In)4 A
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu / AIR)50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles

Mounting & Connection

A9F05104 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Mounting supportDIN rail
Width18 mm
Height91 mm
Depth78.5 mm
Tightening torque (by circuit)2 N.m top or bottom

Environmental

A9F05104 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529

Approvals

A9F05104 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2 EN/IEC 60898-1

Electrical

A9F05104 — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-2

Product details

The Schneider Electric A9F05104 is a 1-pole Acti9 iC60 miniature circuit breaker rated 4 A with a D tripping curve. It sits on a DIN rail, occupies 2 x 9 mm pitches (18 mm wide), and is designed for distribution circuits where high inrush currents — motor starts, transformer energisation, capacitive loads — demand a magnetic trip threshold of 12 x In (±20 %).

Rated Icu of 50 kA at 240 V AC (50/60 Hz) per EN/IEC 60947-2, and an Icn of 6 kA at 230 V AC per EN/IEC 60898-1. That dual-rating means it qualifies for both industrial panel coordination (60947-2 Category A) and residential / commercial final circuits (60898-1). The DC side holds 15 kA at 12–60 V DC and 10 kA at 60–72 V DC — useful for control-power or battery-backed sub-circuits.

Snaps onto standard DIN rail. The double terminal accepts 1–25 mm² rigid or 1–16 mm² flexible at each pole, with a tightening torque of 2 N·m.

Rated insulation voltage 500 V AC, overvoltage category IV. Thermal-magnetic trip unit with D curve — magnetic trip at 12 x In (48 A typical). Electrical endurance 10,000 cycles, mechanical 20,000 cycles.

Frequently asked questions

What is the breaking capacity of A9F05104 at 240 V AC?

50 kA Icu at 220–240 V AC per EN/IEC 60947-2, and 6 kA Icn at 230 V AC per EN/IEC 60898-1.

What does the D curve mean on this breaker?

The D curve trips magnetically at 12 x In (48 A for the 4 A rating), designed for loads with high inrush current such as motors, transformers, and discharge lamps.

Where can I buy A9F05104 and how is it quoted?

The A9F05104 is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
A9F05104