Skip to main content
Schneider Electric A9F05170

Schneider A9F05170 Acti9 iC60 MCB, 0.5 A D Curve 1P

MPN A9F05170
Obsolete

Schneider Electric Acti9 iC60, miniature circuit breaker, 1P, 0.5 A, D curve, 50 kA at 240 V AC, thermal-magnetic, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05170 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F05170 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider A9F05170 is a 1-pole Acti9 iC60 miniature circuit breaker rated at 0.5 A with a D curve. It's a thermal-magnetic MCB built for distribution boards, snapping onto a standard DIN rail.

Breaking capacity is 50 kA Icu at 220...240 V AC per EN/IEC 60947-2, and 6 kA Icn at 230 V AC per EN/IEC 60898-1. That 50 kA rating at typical mains voltage gives you real fault-current headroom in a panel — it's not a residential-grade device. It also carries 15 kA at 12...60 V DC. The part is certified to both the industrial (60947-2) and household (60898-1) standards, so it's accepted across commercial and light industrial builds. Overvoltage category IV means it's rated for the main incoming supply, not just sub-circuits.

Width is 18 mm (2 x 9 mm pitches), height 91 mm, depth 78.5 mm. That's a standard single-module footprint on a DIN rail — no surprises in a populated enclosure. Wire stripping length is 14 mm. IP20 rated, so it's for indoor panel use only.

MPN
A9F05170