Skip to main content
Schneider Electric A9F05203

Schneider Electric A9F05203 Acti9 iC60N MCB, D Curve, 3 A, 2

MPN A9F05203
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, A9F05203, D curve, 3 A, 2P, 50 kA Icu at 415 V AC, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05203 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F05203 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F05203 is an Acti9 iC60N miniature circuit breaker (MCB) rated 3 A, D curve, 2 poles, designed for distribution in AC and DC networks. The D curve is the key selection parameter here: it allows the breaker to ride through the startup surge without opening, while still providing overcurrent and short-circuit protection.

This MCB carries dual certification to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household / similar). The practical difference: under 60947-2 it is rated 50 kA Icu at 380…415 V AC, which is the ultimate breaking capacity — the breaker can safely interrupt a fault up to 50 kA once and still be functional afterward. Under 60898-1 it is rated 6000 A Icn at 400 V AC, the service breaking capacity for residential-grade coordination. The 2-pole version isolates both phase and neutral in single-phase or DC circuits; the suitability-for-isolation marking confirms it can be used as a disconnecting means per both standards.

The double terminals accept 1…25 mm² rigid or 1…16 mm² flexible, with a stripping length of 14 mm and a tightening torque of 2 N.m. IP20 finger-safe terminals for enclosed panel use. The toggle has a contact position indicator and a separate trip indicator window — useful for quickly identifying a tripped breaker without toggling it. Earth-leakage protection requires a separate Vigi iC60 block; this MCB alone does not provide GFCI.

MPN
A9F05203