Schneider Electric A9F05206

Schneider Electric A9F05206 Acti9 iC60N MCB, 6 A, D Curve, 2

MPN A9F05206
Active

Schneider Electric Acti9 iC60N miniature circuit breaker, A9F05206, 6 A rated current, D curve, 2 poles, 36 mm width, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05206 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9F05206 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

Panel-fit and breaking capacity

The A9F05206 is a 2-pole, 6 A miniature circuit breaker from the Acti9 iC60N family, designed for DIN-rail mounting in distribution panels. Its 36 mm width (4 x 9 mm pitches) fits standard modular enclosures; the 78.5 mm depth and 91 mm height leave clearance for gland plates and cable ducts. Rated Icu at 220…240 V AC is 20 kA; at 380…415 V AC it holds 10 kA. Icn per EN/IEC 60898-1 is 6 kA at 400 V AC. For a 6 A device these margins cover most industrial distribution boards without cascading upstream. The D curve magnetic trip operates at 12 x In ±20 %, so it tolerates the inrush of small motors, transformers, or solenoid banks without nuisance tripping on start-up.

Dual-standard certification and lifecycle

Certified to both EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household / similar) — a dual rating that lets the same part serve control-panel distribution and branch-circuit protection under one BOM line. Lifecycle status is current production. Pollution degree 3 per IEC 60947-2 suits environments with conductive pollution or occasional condensation — typical for factory-floor panels not sealed to NEMA 4X.

Connection and wiring

The thermal-magnetic trip unit requires no external power — the breaker is self-powered for overcurrent sensing. IP20 finger-safe terminals are standard for enclosed distribution boards. A separate earth-leakage block (Vigi iC60) can be added on the downstream side for RCD protection without replacing the MCB.