Skip to main content
Schneider Electric A9F05213 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F05213 Acti9 iC60N MCB, 13 A, 2P, D Cur

MPNA9F05213
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 13 A, 2P, D curve, 36 kA Icu at 12-133 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F05213 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameIC60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F05213 — Electrical
ParameterValue
Rated current [In]13 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)DC AC
Network frequency50/60 Hz
A9F05213 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F05213 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F05213 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F05213 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F05213 is an Acti9 iC60N miniature circuit breaker rated at 13 A with a D tripping curve, 2 poles, and a 36 kA Icu breaking capacity at 12-133 V AC per EN/IEC 60947-2.

Breaking capacity is given at multiple voltage levels: 36 kA Icu at 12-133 V AC, 20 kA Icu at 220-240 V AC, 10 kA Icu at 380-415 V AC, and 6 kA Icu at 440 V AC (all per EN/IEC 60947-2). Rated insulation voltage (Ui) is 500 V AC, and the overvoltage category is IV, meaning it is rated for installation at the origin of an electrical installation (e.g., main distribution boards), not just downstream subpanels.

Construction and Integration

The toggle control and trip indicator provide local status. Double terminals on top and bottom accept 1-25 mm² rigid or 1-16 mm² flexible cable; tighten to 2 N·m. Strip length is 14 mm. IP20 rated for finger-safe installation inside an enclosure.

Frequently asked questions

Where can I buy the A9F05213 and get current pricing?

The A9F05213 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings for the A9F05213?

The A9F05213 is a 13 A, 2-pole, D-curve miniature circuit breaker with a breaking capacity of 36 kA Icu at 12-133 V AC and 10 kA Icn at 400 V AC. It complies with EN/IEC 60947-2 and EN/IEC 60898-1.

What is the A9F05213's depth?

The A9F05213 has a depth of 78.5 mm.

What compliance documentation does Schneider provide for the A9F05213?

The A9F05213 is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It is tropicalized to class 2 per IEC 60068-1 and carries pollution degree 3 per EN/IEC 60947-2. Suitability for isolation is confirmed under both standards.

MPN
A9F05213