Skip to main content
Schneider Electric A9F05216

Schneider Electric A9F05216 Acti9 iC60N MCB, 16 A, D Curve,

MPN A9F05216
Active

Schneider Electric Acti9 iC60N, miniature circuit-breaker, 16 A, D curve, 2P, 36 mm, breaking capacity 36 kA Icu at 12-133 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05216 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F05216 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F05216 is a 16 A, D-curve, 2-pole miniature circuit-breaker from the Acti9 iC60N series, built for distribution panels. It sits on a DIN rail, takes up 36 mm (4 x 9 mm pitches), and is rated for both AC and DC networks at 50/60 Hz. The D curve means its magnetic trip fires at 12 x In (±20%), so it handles high inrush currents typical of motor loads, transformers, or discharge lighting without nuisance tripping. For a 16 A breaker, that's around 192 A instantaneous trip threshold. Breaking capacity is the headline: 36 kA Icu at 12-133 V AC, 20 kA at 220-240 V, 10 kA at 380-415 V, and 6 kA at 440 V — all per IEC 60947-2. It also carries a 10 kA Icn at 400 V per IEC 60898-1.

The 36 mm width (2-pole) fits a typical 4-module slot in a consumer unit or distribution board. Terminals accept 1-25 mm² rigid or 1-16 mm² flexible, with a double-terminal design for daisy-chaining or ring-feed. Torque to 2 N·m, strip 14 mm.

Dual-certified to both IEC 60898-1 (the household/industrial MCB standard) and IEC 60947-2 (the industrial circuit-breaker standard). That dual rating gives it a wider acceptance for both residential and industrial specs. Also carries the isolation suitability mark per both standards — you can use it as a disconnector.

MPN
A9F05216