Skip to main content
Schneider Electric A9F05232 — 2-Pole MCB (DIN Rail)

A9F05232 Acti9 iC60 D32 2P MCB, 32 A, 36 kA

MPNA9F05232
Active

Schneider Electric Acti9 iC60 miniature circuit breaker, type A9F05232, D curve, 32 A rated current, 2 poles, 36 kA Icu at 12-133 V AC, DIN-rail mount, thermal-magnetic trip.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F05232 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameIC60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F05232 — Electrical
ParameterValue
Rated current [In]32 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC DC
Network frequency50/60 Hz
A9F05232 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F05232 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F05232 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F05232 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

A9F05232 is a Schneider Electric Acti9 iC60 miniature circuit breaker with a D trip curve, 32 A rated current, and 2 poles. It's a thermal-magnetic unit for AC/DC distribution networks, rated to isolate per EN/IEC 60898-1 and EN/IEC 60947-2. Breaking capacity is 36 kA Icu at 12…133 V AC, 20 kA at 220…240 V, and 10 kA at 380…415 V, with an Icn of 6 kA at 400 V per EN/IEC 60898-1. That's a lot of fault-clearing muscle for a 2-module (36 mm wide) package.

Frequently asked questions

What is A9F05232's depth?

78.5 mm. That's the body depth, not including the toggle handle throw.

What standards does A9F05232 comply with?

Dual-rated to EN/IEC 60947-2 and EN/IEC 60898-1. That means it's certified for both industrial (60947-2) and residential/commercial (60898-1) applications — useful for a panel that needs to meet both a local code and a machine directive.

Where can I buy A9F05232 and how do I get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for this order code.

MPN
A9F05232